Table 9:
Reproducibility
Hysteresis
Table 10:
Electronics
Supply voltage
Admissible harmonic content
Power consumption
Input current resistance (set point)
Current output (actual value), external
working resistance
Table 11:
Standards and directives complied with
RL 93/97 EEC:
DIN EN 61010-1:
DIN EN 61000-6-2:
DIN EN 61000-6-4:
AVENTICS
Reproducibility
0.01 bar
(0.15 psi)
0.005 bar
(0.073 psi)
0.03 bar
(0.435 psi)
Hysteresis
0.03 bar
(0.44 psi)
0.015 bar
(0.218 psi)
0.09 bar
(1.31 psi)
24 V DC (+30%/–20%)
Only use a power pack with safe isolation for the voltage
supply
5%
Max. 1.4 A
Supply voltage switched on: 100 Ω
Supply voltage switched off: highly resistive
< 300 Ω
"Electromagnetic compatibility" (EMC directive)
"Safety requirements for electrical equipment for measurement, control, and
laboratory use", part 1: general requirements
"Electromagnetic compatibility" (interference immunity for industrial areas)
"Electromagnetic compatibility" (interference emission for industrial areas)
| ED07 | R41400766–BDL–001–AB
Outlet pressure
At 6 to 10 bar
(87/145 psi)
At –1 to 1 bar
(–14.5 to 14.5 psi)
At 16 to 20 bar
(232/290 psi)
Outlet pressure
At 6 to 10 bar
(87/145 psi)
At –1 to 1 bar
(–14.5 to 14.5 psi)
At 16 to 20 bar
(232/290 psi)
75