KENMORE ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
8. For typical under counter installation of an electric built-in oven see Figure below.
Only certain cooktop models may be installed over
certain built-in electric oven models. Approved
cooktops and built-in ovens are listed by the MFG
ID number and product code (see the insert sheet
included in the literature package and cooktop
installation instructions for the dimensions).
To reduce the risk of
personal injury and
tipping of the wall
oven, the wall oven
must be secured to
the cabinet (s) by
mounting brackets.
208/240 Volt junction box
for built-in oven.
* If no cooktop is installed directly
over the oven unit, 5" (12.7cm)
maximum is allowed above the
floor.
TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN
(and Optional Electric or Gas Cooktop Combination)
Approx. 3"
(7.5 cm)
G
4 1/2" (11.5cm) Max.*
27" (68.6cm)
Wall oven
30" (76.2cm)
Wall oven
WITH AN ELECTRIC COOKTOP MOUNTED ABOVE
Cabinet side filler panels are
necessary to isolate the unit
from adjoining cabinets.
Cabinet side filler height
should allow for installation
of approved cooktop models
F
Use 3/4" (1.9cm) plywood, installed on
two runners, flush with toe plate. Base
must be capable of supporting 150
pounds (68 kg) for 27" models and
200 pounds (90 kg) for 30" models.
Cut an opening in wood base minimum 9" x 9"
(23 X 23cm), 2" (5cm) from left side filler panel,
to route armored cable to junction box.
CUTOUT DIMENSIONS
F. WIDTH
G. DEPTH
24
/
" (63.2cm) Min.
7
8
23½" (59.7cm)
25¼" (64.1cm) Max.
28½ (72.4cm) Min.
23½" (59.7cm)
29" (73.7cm)
7
36" Min.
(91.4 cm) Min.
H
H. HEIGHT
27¼" (69.2cm) Min.
28½ (72.4cm) Max.
27¼" (69.2cm) Min.
28½ (72.4cm) Max.