Direct Wire Connection - Sears Kenmore 11091942710 Instrucciones De Instalación

Secadora comercial
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ELECTRIC DRYER ELECTRICAL CONNECTIONS
Connecting 3-Wire Connection: Power Supply Cord (cont.)
3. Connect remaining wires under outer terminal block screws (F).
Tighten screws. Finally, reinstall terminal block cover to dryer
rear panel. Secure cover with hold-down screw. Now go to
"Venting Requirements."

Direct Wire Connection

Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected
to green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, re, or
electrical shock.
Remove Terminal Block Cover
Remove hold-down screw and terminal block cover.
20
Fire Hazard
F
F
Direct Wire Strain Relief
1. Insert strain relief.
Unscrew the removable conduit connector (A) and any screws
froma3/4"(19mm)ULListedstrainrelief.Putthethreaded
section of the strain relief (C) through the hole below the terminal
block opening (B). Reaching inside the terminal block opening,
screw the removable conduit connector (A) onto the strain
relief threads.
2. Insert conduit into strain relief and tighten clamp.
Put direct wire cable through the strain relief. The strain relief
shouldhaveatightfitwiththedryercabinetandbeina
horizontal position. Tighten strain relief screw against the direct
wire cable.
A
B
C
Tabla de contenido
loading

Tabla de contenido