8. Mounting
8.3 Mount the receiver
Advice:
• Only connect low voltage or mains voltage devices!
• Lead the cables for low voltage and mains voltage only through
separate screwings!
- The maximum load for the relay contacts is as follows:
30 V DC:
230 V AC:
- The nominal voltage of the fuse / power safety switch may not
exceed the load values listed up in the table of loads.
Attention!
During programming the unit is under voltage!
• Remove the protective cover.
• Mount the enclosed screw set to the unit.
• Fix the bottom of the housing with the screws to the wall.
• Connect the supply cable and the devices to be actuated according to the
connection plan.
• Connect the external impulse buttons, if necessary
(Connection terminals X201 - X203).
Attention!
Only potential-free contacts may be used
• Switch on the unit and carry out a functional check.
• Program the operating modes.
• Put back the protective cover.
180 W or
3.680 W