Technical Data - Aventics EBS-ET Serie Instrucciones De Servicio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

AVENTICS | EBS-ET-...-VE | R412013037–BDL–001–AB | English
1
Device description
1 M4 mounting bores
2 Vacuum connection
3 Compressed air connection
4 Exhaust connection/silencer
Function
The ejector is supplied with compressed air via connection (3). The compressed air
flowing through generates a vacuum at connection (2) and is blown off to the outside
via exhaust openings (4). The following functions are possible, depending on the
design:
W
The vacuum can be switched on and off via an electromagnetic valve (6).
W
A blow-off pulse can be generated via an electromagnetic valve (7) or
pneumatically via an accumulator (8).
W
A pressure sensor (5) makes it possible to recognize the presence of a vacuum
and to generate a switch pulse.
6
Assembly
Connecting the ejector pneumatics
O See the EBS-PT operating instructions (R412008280).
Connecting the ejector electrics
System is operating under voltage.
Working on the system when under voltage could lead to injuries from an electric
shock and damage to the components!
O Make sure that all relevant system parts are not under voltage before working
on the system.
Connecting the electromagnetic valve
(only for versions with an electromagnetic valve)
Use connector type 10/15, MNR 1834484253 to connect the electromagnetic
valve. (Not included in the delivery contents. Order separately.)
1. Wire the open cable side with your system.
No polarity must be observed when applying +24 V DC (bipolar).
2. Insert the connector in the socket on the electromagnetic valve until it engages.
2
Connecting the PE6 pressure sensor
M8x1 plug
Pin
Signal
1
+UB: 24 V supply
2
4
2
Out 2: switch output 2, PNP (green LED)
1
3
3
GND: reference potential
4
Out 1: switch output 1, PNP (yellow LED) black
1) Max. cable length: 30 m
Notes on installation:
W
Install lines that are as short as possible to avoid malfunctions.
W
Connect the line shield to an interference-free ground potential. The shield is not
connected to the sensor.
7
Commissioning
1. Make sure before commissioning that all the connections on the ejector are
properly connected and all the plastic tubing is firmly fitted.
2. Apply the compressed air to the system.
3. Check whether the necessary vacuum has been attained
(e.g. with a pressure gauge).
If using electromagnetic valves:
O Test the function of the electromagnetic valves.
If using a pressure sensor:
O Test the function of the pressure sensor.
5 Pressure sensor with 2x LED
6 "Suction" electromagnetic valve
7 "Blow-off" electromagnetic valve
8 Accumulator for blow-off pulse
CAUTION
Cable
brown
white
blue
8
Operation
Heating of the pressure sensor during operation
At high ambient temperatures and low load impedance, the pressure sensor may
heat up to over 60 °C during operation, resulting in a danger of burns.
O Do not touch the pressure sensor during operation or shortly thereafter.
O See the EBS-PT operating instructions (R412008280).
9
Maintenance
The ejector is maintenance-free.
Please contact the service department at AVENTICS if you have any technical
problems.
10 Accessories
Accessory part
Connecting cable with bushing for solenoid
valves (3 m)
CN 1 connection cable for pressure sensor,
M8 push-in fitting 4-pin
Vacuum filter, cup version VFC, required
with heavy contamination on the suction
side or with fine dust < 50 μm
11 Cleaning and servicing
Solvents and aggressive cleaning agents
Solvents and aggressive cleaning agents could damage the ejector.
O Only use water for cleaning and, if necessary, a mild detergent.
How to clean the ejector:
1. Make sure that all relevant system parts are not under voltage or pressure.
2. Clean the ejector using a slightly damp cloth. Only use water to do this and, if
necessary, a mild detergent.
12 Disassembly and malfunctions
1)
O See EBS-PT operating instructions (R412008280), chapter 11 "Disassembly" and
chapter 13 "If malfunctions occur".
13 Disposal
Dispose of the ejector in accordance with the applicable national regulations.

14 Technical data

Electromagnetic valve
Operating voltage
Power
ED
On/off switching time
Manual override
Protective circuit
Switching state
Protection class
CAUTION
Description/art. number
1834484144...147
Filter size G1/8, G1/4, G1/2, G3/4
0821305181...187
NOTICE
+24 V DC (-5/+10 %)
Protective extra-low voltage
(PELV acc. to IEC 364-4-41)
Z-diode (in valve)
IP 40 (with plug)
4
1834484253
1.3 W
100 %
8/10 ms
Depression
Via LED
Tabla de contenido
loading

Tabla de contenido