ASSEMBLY ROTATING BRUSHES
1. Push downwards the control lever to lift the brushes base
Note In case of machines with automatic control (machines with actuator) rotate the
Note
Note
Note
switch with key into position ON (1) and push the lever button (2) upwards so
much until the signal lamp of the up-down brushes base is coming off.
2. Turn the key into position OFF and take it off from the instrument board (1)
ATTENTION!
ATTENTION! To carry out the operations of brushes assembly with
ATTENTION!
ATTENTION!
connected current can cause serious damage to the hands.
3. With the brushes base in lifted position, insert the brushes into the seat of the plate
under the base until the three buttons fit into the holes of the plate. Turn the brush
so that the buttons are pushed towards their retaining springs until the brush is
clamped in place. The figure shows the direction of rotation for the coupling of the
brushes.
4. It is recommended to invert daily the position of the right brush with the left one and
vice versa. If the brushes are not new and they show deformed bristles, it is better to
reassemble them in the same position, in order to avoid that the different inclination
of the bristles causes an overload to the brushes motor and excessive vibrations.