PLS
10. Technical data PLS 101-312
The most important technical data of the PLS are listed below.
Note:
If you wish to use one or more PLS devices in conjunction with
a SICK LSI (Laser Scanner Interface), then please also refer
to the technical data of the LSI (see LSI technical description).
Electrical data
The characteristics are measured at the connection corner
(unless otherwise specified).
Properties
Supply voltage (Uv)
Reverse-polarity protected, via isola-
ting transformer to EN 60742 (also
vehicle charger)
Permissible residual ripple (V
The supply voltage limits must not be
exceeded or undershot.
Response time (adjustable
via scan rate)
double-speed
sixteen-speed
Power-up times
On voltage ON
Power consumption (no load)
182
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
min.
16.8 V
)
RMS
8 008 321/M844/06-05-02 Operating Instructions • PLS
GB
Data
type
max.
24.0 V
28.8 V
500 mV
2 x 40 ms
16 x 40 ms
6 s
17 W