OBJ_BUCH-2825-002.book Page 16 Wednesday, August 24, 2016 4:01 PM
16 | English
that the vertical laser line runs through the already marked
point I. Allow the measuring tool to level in and mark the
cross point of the laser lines on the wall A (point III).
– The difference d of both marked points I and III on wall A
indicates the actual height deviation of the measuring tool.
The maximum permitted deviation d
lows:
d
= double distance of the walls x 0.3 mm/m
max
Example: With a 5 metre distance between the walls, the max-
imum deviation must not exceed
d
= 2 x 5 m x 0.3 mm/m = 3 mm. Thus, the marks must not
max
be more than 3 mm apart.
Checking the Levelling Accuracy of the Horizontal Line
For the check, a free surface of approx. 5 x 5 metres is re-
quired.
– Mount the measuring tool between both walls A and B onto
the holder or a tripod, or place it on a firm and level sur-
face. Allow the measuring tool to level in.
A
– At a distance of 2.5 metres from the measuring tool, mark
the centre of the laser line (point I on wall A and point II on
wall B) on both walls.
A
B
– Set up the measuring tool 5 metres away turned by 180°
and allow it to level in.
– Align the height of the measuring tool (using a tripod or by
underlaying, if required) in such a manner that the centre
of the laser line is projected exactly against the previously
marked point II on wall B.
1 609 92A 3G0 | (24.8.16)
– Mark the centre of the laser line as point III (vertically
above or below point I) on the wall A.
– The difference d of both marked points I and III on wall A
indicates the actual deviation of the measuring tool from
the level plane.
is calculated as fol-
The maximum permitted deviation d
max
lows:
d
max
Example: With a 5 metre distance between the walls, the max-
imum deviation must not exceed
d
max
be more than 3 mm apart.
Checking the Levelling Accuracy of the Vertical Line
For this check, a door opening is required with at least 2.5 m
of space (on a firm surface) to each side of the door.
– Position the measuring tool on a firm, level surface (not on
a tripod) 2.5 m away from the door opening. Direct the la-
ser beams at the door opening and allow the measuring
tool to level in.
B
– Mark the centre of the vertical laser line at the floor of the
door opening (point I), at a distance of 5 m beyond the
other side of the door opening (point II) and at the upper
edge of the door opening (point III).
– Position the measuring tool on the other side of the door
opening directly behind point II. Allow the measuring tool
to level in and align the vertical laser line in such a manner
that its centre runs exactly through points I and II.
max
= double distance of the walls x 0.3 mm/m
= 2 x 5 m x 0.3 mm/m = 3 mm. Thus, the marks must not
is calculated as fol-
Bosch Power Tools