1
General data
Designation
Product-line SensyTemp MI-iZ und IS-iZ and all product variants based thereupon, such as
SensyTemp MP-iZ, WT-iZ, TW-iZ, ET-iZ, IS-iZ etc.
Purpose of application
Temperature detecting devices, resistance thermometers and thermocouples are used for
thermometry in the most different fields of application. They may be used with and without pro-
tecting well.
Type of protection
Intrinsically safe "i", category ia or ib
Marking
II 1 G EEx ia IIC T6 or II 2 G EEx ib IIC T6 or II 1/2 G EEx ib IIC T6
Additional Ex-marking
Temperature detecting device (resistance thermometer or thermocouples) with protecting well
for the use in zone 0..
Temperature detecting device (resistance thermometer or thermocouples) without protecting
well for the use in zone 0. .
Temperature detecting device (resistance thermometer or thermocouples) without protecting
well for the use in zone 1.
Use with / without suitable protecting well (separative element according to EN 50284)
Zones
With protecting well
Zone 0
II 1/2G EEx ib II C T6
Zone 1
II 2G EEx ib II C T6
42/10-59 XU
II 1/2 G EEx ib IIC T6
PTB 01 ATEX 2200 X
0 1 0 2
II 1 G EEx ia IIC T6
PTB 01 ATEX 2200 X
0 1 0 2
II 2 G EEx ib IIC T6
PTB 01 ATEX 2200 X
0 1 0 2
Without protecting well
II 1G EEx ia II C T6
II 2G EEx ib II C T6
SensyTemp MI, IS
2002
2002
2002
GB 3