=> Cut off power to the installation and disconnect the earth of the installation
=> Set the switch to 2P or 3P.
=> Then connect the measuring cables to the instrument and to the rods, complying with the following
distances and connections (example of connection for 3P measurement).
Remark : to be sure that rod S is located in a zone that is not influenced by other earth electrodes, move it
( 10% of the distance and repeat the measurement. The result must not change or just from few %.
4.2.3
MEASUREMENT PROCEDURE
Press the TEST key. The instrument measures voltages U
instrument checks the resistances of rods S and H: if they are correct, the instrument makes the measurement
and displays it.
To make a 2P measurement, plant a single rod and connect the measuring cables to terminals H and E of the
instrument. The measurement proceeds in the same way as a 3P measurement.
4.2.4
MEASUREMENT RESULTS
After the measurement, the measured values and complementary results can be consulted using the
and
keys.
MORE
(The quantities accessible before the measurement is made are described in § 4.1.4)
Parameters accessible in the 2P setting :
Initial display
Initial display
Pressing the
or
MORE
MORE
(1
st
press)
R
H
H
z
R
U
E
HE
key once more causes a return to the initial display.
60
and U
. If the measurement is possible, the
HE
SE
MORE
nd
(2
press)
R
E ALARM
-------
MORE
nd
(3
press)
R
∆ ∆ ∆ ∆ ∆ E
U
L
Tabla de contenido
loading

Tabla de contenido