cleanup

Special cleanup instructions for use with
flammable solvents:
• Always flush spray gun preferably outside and at least one
hose length from spray pump.
• If collecting flushed solvents in a one gallon metal
container, place it into an empty five gallon container, then
flush solvents.
• Area must be free of flammable vapors.
• Follow all cleanup instructions.
IMPORTaNT: The sprayer, hose, and gun should be cleaned
thoroughly after daily use. Failure to do so permits material
to build up, seriously affecting the performance of the unit.
always spray at minimum pressure with the gun
spray tip removed when using mineral spirits or
any other solvent to clean the sprayer, hose, or
gun. Static electricity buildup may result in a fire
or explosion in the presence of flammable vapors.
1. Follow the "Pressure Relief Procedure" found in the
Operation section of this manual.
2. Remove the gun tip and tip guard and clean with a brush
using the appropriate solvent.
3. Place the siphon tube into a container of the appropriate
solvent (refer to recommendations of the material
manufacturer). An example of the appropriate solvent is
water for latex paint.
4. Place the return hose into a metal waste container.
5. Turn the PRIME/SPRAY knob to the
PRIME position.
6. Start the engine.
7. Slowly turn the DirectLink pressure control
knob counterclockwise to increase the
pressure until fluid starts to come out of the return hose.
Use only enough pressure to keep the fluid coming out.
8. Allow the fluid to circulate through the sprayer and flush
the paint out of the return hose into the metal waste
container.
9. Turn off the sprayer by pressing and holding the engine
shutoff switch until the motor shuts off.
10. Place a metal waste container underneath the spray gun
to catch the paint and solvent.
11. Start the engine.
12. Turn the PRIME/SPRAY knob to the
SPRAY position.
13. Turn the DirectLink pressure control knob
slowly counterclockwise to increase the
pressure.
14. Fully pull the spray lever on the cart
handle to trigger the spray gun. Fluid will begin flowing
through the spray hose and out of the gun.
15. Continue to pull the spray lever on the cart handle until the
material is flushed out of the hose and the solvent coming
out of the gun is clean.
16. Release the spray lever.
NOTE: For long-term or cold weather storage, pump
Pump Saver™ through the entire system.
17. Follow the "Pressure Relief Procedure" found in the
Operation section of this manual.
18. Store the sprayer in a clean, dry area.
IMPORTaNT: Do not store the sprayer under pressure.
© Titan Tool Inc. All rights reserved.

Special cleanup

IMPORTaNT: Perform the following procedure after
spraying with water-based materials only.
Perform the following procedure when the valves of the sprayer
are stuck or when preparing the sprayer for long term storage.
The use of a pump cleaning adapter that attaches to the bottom
of the siphon tube is required (the pump cleaning adapter is
included with the sprayer).
1. Lock the gun and remove the spray tip assembly. If
necessary, loosen the gun holder clamp knob and then
engage the spray gun trigger lock. Move the spray gun
to its original position and tighten the clamp knob. Place
the suction tube and return tube into an empty waste
container.
2. Using a garden hose, rinse off the siphon tube, return
hose and inlet filter. Empty the waste container.
3. Remove the inlet filter
from the suction tube
and place into a waste
container.
4. Verify that the seals
are present inside the
adapter and suction
tube. Thread the pump
cleaning adapter onto a
garden hose. Connect
the hose and adapter to
the fitting on the end of
the siphon tube.
5. Unclip the return hose
from the siphon tube and
place it into the waste
container.
6. Turn the PRIME/SPRAY knob to the PRIME position.
7. Turn on the water supply.
8. Start the engine. Water will go into the siphon tube and
out through the return hose. Let the sprayer run for a few
minutes to allow the return hose to be flushed.
9. Turn off the sprayer by pressing and holding the engine
shutoff switch until the motor shuts off.
10. Place a metal waste container underneath the spray gun
to catch the cleaning solution.
11. Start the engine.
12. Turn the PRIME/SPRAY knob to the SPRAY position.
13. Turn the DirectLink pressure control knob slowly
counterclockwise to increase the pressure.
14. Fully pull the spray lever on the cart handle to trigger the
SPRAY
spray gun. Fluid will begin flowing through the spray hose
and out of the gun.
15. Continue to pull the spray lever on the cart handle until the
material is flushed out of the hose and the water coming
out of the gun is clean.
16. Release the spray lever.
17. Follow the "Pressure Relief Procedure" found in the
Operation section of this manual.
9
Siphon
tube
Pump
cleaning
adapter
Seals
Garden
hose