Function
Auto-stop with fastening
The preset fasten-
completion
ing torque has been
achieved and the tool
has stopped.
Alarm against insuffi-
The preset fastening
cient fastening
torque has not been
achieved, because
the switch trigger has
released before complet-
ing the fastening.
Alarm for low battery
The battery power
capacity
became low and it is
time to replace the
battery cartridge.
Auto-stop with low
The battery power is
remaining battery
almost used up and the
capacity
tool stopped.
Check of the LED indi-
When the battery
cator, light and beeper
cartridge is installed,
operation
the tool checks for its
LED indicator, light and
beeper.
Anti-reset of controller
The battery voltage
dropped abnormally for
some reason, and the
tool stopped.
Overheat protection
Tool's controller heated
up abnormaly and the
tool stopped.
Detection of switch
When the battery car-
trigger operation when
tridge is installed with
installing battery
the switch trigger pulled,
the tool stops to avoid
unintentional start.
Motor failure detection
Motor failure has been
detected. At this time,
tool does not work.
Double-hitting detection
When the operator
starts to re-fasten an
already-fastened screw,
the tool detect it and
stops.
Maintenance alarm
A maintenance time has
come according to your
preset number of screws
driven.
Alarm for unavailable
Data cannot be
data communication
exchanged between the
(with the tool in connec-
tool and PC in spite of
tion with PC)
the connection.
Indication that data com-
The tool is connected to
munication is available
PC and data communi-
(with the tool in connec-
cation is available.
tion with PC)
Status of the tool
Lights up in green for
approximately one
second.
Lights up in red.
Flickers in red slowly.
Lights up in red.
Lights up first in green,
next red.
(And then the light
comes on.)
Flickers in red and green
alternatively.
Flickers in red quickly.
Flickers in red and green
alternatively.
Flickers in red and green
alternatively.
Lights up in red.
Flickers in yellow.
Flickers in yellow.
Flickers in green.
Status of the LED indicator/beeper
LED indicator
A long beep
A series of long beeps
A long beep
A series of very short
beeps
A series of short beeps
A series of short beeps
A series of short beeps
A series of short beeps
A long beep
7 ENGLISH
Action to be taken
Beeper
–
Retighten the screw.
Replace the battery with
fully charged one.
Replace the battery with
fully charged one.
Replace the battery with
fully charged one.
Remove the battery car-
tridge immediately and
cool the tool down.
Release the switch
trigger.
Ask your local Makita
Service Center for repair.
–
Reset the alarm with the
application software.
–
Restart the application
software and re-connect