ON
Activates photocell check
OFF Deactivates photocell check
If this setting is not activated (OFF), it inhibits the photocell checking
function, allowing connection of devices not provided with additional
checking contact.
Gate-open or 2nd radio channel warning light (SCA 2ch) [ OFF ]
-
ON
The output between terminals 21 and 22 is configured as Gate-open
warning light, in this case the 2nd radio channel controls pedestrian
opening.
OFF The output between terminals 21 and 22 is configured as 2nd radio
channel.
Motors in operation (1 mot ON) [ OFF ]
-
ON
Only motor 2 is in operation (terminals 3, 4 and 5).
With this configuration, the pedestrian input is disabled.
OFF Both motors are in operation.
Lock hold (block persist) [ OFF ] (Fig. 5)
-
ON
To be used when the mechanical closing backstop is fitted.
This function activates leaf pressure on the mechanical backstop, without
this being considered as an obstacle by the Ampere-stop sensor.
Therefore the rod continues its travel for another 0.5 sec. after
detecting the closing limit switch or upon reaching the mechanical
backstop. So by activating the closing limit switches slightly earlier,
the leaves will come to a perfect halt against the backstop. (Fig. 5a)
OFF To be used when no mechanical closing backstop is fitted.
Movement is exclusively halted by activation of the closing limit
switches; in this case proceed to carrying out precise setting of the
closing limit-switch activation. (Fig. 5b)
-
Hold-to-run control (hold-to-run) [ OFF ]
ON
Hold-to-run operation: the manoeuvre continues as long as the
control key is kept pressed.
WARNING!: Enabling the Hold-to-run logic entails a different use of
the START and PEDESTRIAN buttons:
START takes on the hold-to-run OPEN function
PEDESTRIAN takes on the hold-to-run CLOSE function
OFF Impulse operation, according to the 3 or 4 step logic.
Fixed code (fixed code) [ OFF ]
-
(UNIPRO ⇒ Advanced logics ⇒ address 13)
ON
The receiver is configured for operation in fixed-code mode, see
paragraph on "Radio Transmitter Cloning".
OFF The receiver is configured for operation in rolling-code mode, see
paragraph on "Radio Transmitter Cloning".
Radio transmitter programming (radio prog) [ ON ]
-
(UNIPRO ⇒ Advanced logics ⇒ address 15)
ON
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode by
means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2,
T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new
transmitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio
menu.
- Master/Slave (Master) [ OFF ]
ON
The control panel is set as Master in a centralised connection (see
Paragraph 7).
OFF The control panel is set as Slave in a centralised connection (see
Paragraph 7).
Start-Open selection (start - open) [ OFF ]
-
ON
The input between the two terminals 15-16 acts as open
OFF The input between the two terminals 15-16 acts as start
6.3) RADIO MENU (RADIO)
-
Add
Allows you to add one key of a radio control device to the receiver
memory; after storage it displays a message showing the receiver
number in the memory location (from 01 to 64).
Add Start button (add start)
associates the required key to Start command
Add 2ch button (add 2ch)
associates the required key to 2nd radio channel
-
Read (read)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 64), and the key
number (T1, T2, T3 or T4).
Eliminate list (erease 64)
-
WARNING! Completely removes all memorised radio control devices
14 - LIBRA-MA-R - Ver. 04
INSTALLATION MANUAL
from the receiver memory.
-
Receiver code reading (RX code)
This displays the code entered in the receiver (par. 11).
Consult paragraphs 8, 9, 10 and 11 for further information concerning
the advanced functions of the Clonix incorporated receiver.
6.4) LANGUAGE MENU (language)
Allows you to set the language on the display programmer.
-
ITALIAN (ITA)
-
FRENCH (FRA)
-
GERMAN (DEU)
-
ENGLISH (ENG)
-
SPANISH (ESP)
6.5) DEFAULT MENU (default)
Restores the preset default values on the control unit. After restoring, a new
autoset operation must be carried out.
6.6) DIAGNOSTICS AND MONITORING
The display on the LIBRA-MA-R panel shows some useful information,
both during normal operation and in the case of malfunctions.
Diagnostics:
In the case of malfunctions, the display shows a message indicating which
device needs to be checked:
STRT = START input activation
STOP= STOP input activation
PHOT= PHOT input activation
FLT = FAULT input activation for checked photocells
In the case where an obstacle is found, the LIBRA-MA-R panel stops the
door and activates a reverse manoeuvre; at the same time the display
shows the "AMP" message.
Monitoring:
During the opening and closing phases, the display shows four digits
separated by a dot, for example 35. 4 0. The digits are constantly updated
during the manoeuvre, and represent the maximum torque reached by
motor 1 (35) and motor 2 (40).
These values allow the torque setting to be corrected.
If the maximum torque value reached during the manoeuvre gets sensibly
close to the value set in the parameter menu, malfunctions may occur in the
future following wear or slight door deformation.
It is therefore advisable to check the maximum torque reached during some
of the manoeuvres carried out in the course of installation, and if necessary
set a value about 15-20 percent points higher in the parameter menu.
6.7) AUTOSET MENU (autoset)
Allows you to automatically set the Motor torque.
WARNING!! The autoset operation is only to be carried out after checking
the exact leaf (opening/closing) movement, and correct limit-switch
activation.
As soon as the OK pushbutton is pressed, the ".... ...." message is
displayed, and the control unit executes an opening manoeuvre followed by
a closing manoeuvre, during which the minimum torque value needed for
leaf movement is automatically set.
During this phase, it is important to avoid obscuring the photocells, as well
as using the START, STOP or PED commands and the display.
After this, if autosetting has been successfully completed, the control unit
displays the "OK" message and, after pressing any key, returns to the
Autoset menu.
If, on the other hand, the control unit displays the "KO" message, it means
that the autoset procedure has not been successfully completed; it is thus
necessary to check the wear condition of the gate and the regular movement
of the leaves before proceeding to a new autoset operation.
WARNING! During the autoset phase, the obstacle detection function is not
active, therefore the installer must control the automation movement and
prevent persons and things from approaching or standing within the
automation working range.
In the case where buffer batteries are used, autosetting must be carried out
with the control panel supplied by mains power voltage.
WARNING: Check that the impact force value measured at the
points established by the EN 12445 standard is lower than that
specified in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.
7) STATISTICS
Having connected the UNIPRO programmer to the control unit, enter the
Tabla de contenido
loading