Maintenance And Repairs - EBARA 3SF Manual De Instrucciones De Empleo Y Manutención

Ocultar thumbs Ver también para 3SF:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
vention when the limit values are exceeded must
be FAILURE SAFE.
TAB.1: Classification of the maximum surface tem-
perature for apparatuses belonging to group II G (in
accordance with the EN 13463-1 norm)
Maximum pump
Temperature
classification surface temperature
[°C]
T1
450
T2
300
T3
200
T4
135
T5
100
T6
85
TAB. 2: Maximum temperature of the fluid in accor-
dance with the temperature classification
Maximum temperature of the
fluid [°C]
90 / 110 *
90 / 110 *
90 / 110 *
80
*) Technical datum given in paragraph of the User
and Maintenance Manual of the product 3SF-3-
LSF-3PF-3LPF.

8. MAINTENANCE AND REPAIRS

Please refer to paragraph of the instruction booklet
for information on maintenance and repairs.
In addition, the pump must never be cleaned using
dry cloths (rubbing with dry cloths made of pure
polyamide material or cotton, for example, can
cause electric discharges).
Some pump models have a bearing on the joint.
No maintenance needs to be carried out on the
bearings, which should work for 10,000 hours at a
temperature of 40°C without problems.
When replacing or controlling the bearings, the
user must contact the retailer or the help service.
The same is true for the seal.
Verify, proportionally to the operation conditions,
that the compression ratio is lower than the spon-
taneous ignition limit of the processed fluid.
Correct motor alignment is indispensable for pre-
venting vibrations and faulty bearings.
Gas or vapour
mix ignition
temperature
[°C]
>450
>300
>200
>135
>100
>85
Temperature
classification
T1
T2
T3
T4
3SF-3LSF-3PF-3LPF – 9
Tabla de contenido
loading

Este manual también es adecuado para:

3lsf3p, 3lpf

Tabla de contenido