Shaking The Primary Filter; Emergency Stopping; Emptying The Dust Container; Plastic Bag - Nilfisk cfm T26 Plus Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Shaking the primary filter

Figure 8-9
Depending on the vacuumed dust quantity and if the pointer
of the vacuum gauge switches from the green zone (3, Fig.
8) to the red zone (2, Fig. 8), turn the vacuum cleaner off and
shake the main filter with the knob (1, Fig. 9).
WARNING!
Stop the vacuum cleaner before shaking the filter.
Do not shake the filter while the vacuum cleaner is on,
as this could damage the filter itself.
Wait a few seconds before restarting the vacuum cleaner,
to allow the dust to settle. Replace the filter element if the
pointer still remains in the red zone (1, Fig. 8) even after the
filter has been shaken (consult the "Primary filter replacement"
paragraph).

Emergency stopping

Turn the main switch to "0" position.

Emptying the dust container

WARNING!
Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.
Before emptying the container it is advisable to shake the filter
(see "Shaking the main filter" paragraph).

Plastic bag

A plastic bag can be used to collect dust (see Fig. 10).
In this case, the vacuum cleaner must be equipped with
optional accessories [depressor (3) and grid (2), Fig. 10].

Liquids vacuuming

WARNING!
Make sure that the vacuum cleaner is equipped with
a liquid level sensor and is suitable for vacuuming
liquids.
The filter element will be wet after liquids have been
vacuumed.
A wet filter element can quickly become clogged if the
vacuum cleaner is then used to vacuum dry substances.
For this reason, make sure that the filter element is dry
or replace it with another one before using the vacuum
cleaner for dry materials.
02/2013

At the end of a cleaning session

Turn off the vacuum cleaner and remove the plug from
the socket.
Wind the connection cable around the handle (Fig. 11).
Empty the container as described in the "Emptying the
container" paragraph.
Clean the vacuum cleaner as described in the paragraph

"Maintenance, cleaning and decontamination".

Wash the container with clean water if aggressive
substances have been vacuumed.
Store the vacuum cleaner in a dry place, out of reach of
unauthorized people.
Maintenance, cleaning and
decontamination
WARNING!
The precautions described below must be taken
during all maintenance operations, including cleaning
and replacing the primary and HEPA filters.
WARNING!
The maintenance, cleaning and decontamination
operations must only be performed with the vacuum
cleaner turned off and the plug disconnected from the
power socket.
It is absolutely forbidden to perform maintenance with
the plug connected to the socket.
Danger of electric shock!
If the user is performing the maintenance operations,
the vacuum cleaner must be disassembled, cleaned
and overhauled as far as reasonably possible without
hazards for the maintenance personnel or other people.
The suitable precautions include decontamination before
disassembling the vacuum cleaner, adequate filtered
ventilation of the exhaust air from the room in which it
is disassembled, cleaning the maintenance area and
suitable personal protection.
WARNING!
This vacuum cleaner can be equipped with a
HEPA filter for vacuuming dust hazardous to one's
health. The procedures for servicing and emptying
the vacuum cleaner including removing the dust
container, must only be performed by specialised
personnel wearing protective clothing. Do not use
without the complete filter system in place.
All parts of the vacuum cleaner must be considered
contaminated when they are removed from the
hazardous zone and appropriate actions must be taken
to prevent the dispersion of dust.
When maintenance or repair procedure are carried out,
all the contaminated elements that cannot be properly
cleaned, must be eliminated.
These elements must be disposed of in sealed bags
conform to applicable regulations and in accordance with
the local laws governing the disposal of such material.
This procedure must also be followed when the filters are
eliminated (primary and HEPA filters).
Compartments that are not dust-tight must be opened
with suitable tools (screwdrivers, wrenches, etc.) and
thoroughly cleaned.
9
T26 Plus - T48 Plus - T63 Plus
US
C386

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

T48 plusT63 plus

Tabla de contenido