In order to measure digital channels correctly, previously, the channel must be
defined as digital (see Edit Channel Plan function at section '4.2.1 Global
Configuration menu) and, if necessary, the CHANNEL BW parameter should be
redefined by means of the Channel-Frequency configuration menu. When a
channel has been defined as digital, the PROMAX-10
central frequency.
Digital channels power measurement is carried out by means of an integration
method. The PROMAX-10
Premium
BW) in sections of 230 kHz (4 by each MHz approximately) and measures the
contribution of each one to the total power of the channel. This way, a very exact
measurement is obtained, specially in the case of degraded channels, because the
channel flatness is had in consideration.
Figure 20.- Measuring the power of a digital channel by integration.
The C/N ratio measurement shows the ratio between the digital channel power
and the noise power. The user can define the frequency where the noise power must be
measured. Two possibilities exist:
I. Absolute method
Selecting in the Channel-Frequency configuration menu the NOISE MODE
parameter as FREQ, the equipment will interpret the NOISE FREQ. value as the
frequency where the noise power measurement must be done. Naturally the user must
be sure that the NOISE FREQ. value corresponds with a free channel.
II. Relative method
Selecting in the Channel-Frequency configuration menu the NOISE MODE
parameter as F, the unit will make the measurement of noise at the frequency obtained
to add to the tuning frequency (channel central frequency) the value defined for the
NOISE FREQ. parameter. The PROMAX-10
= BW/2 + 0.5 MHz, where BW is the channel bandwidth defined in the channel plan,
thus for example, if it is desired to measure the C/N ratio of a digital channel with a
bandwidth (BW) of 8 MHz, NOISE FREQ. will take as value 4.5 MHz. The Channel-
Frequency configuration menu allows the user to redefine this parameter; when tuning a
new channel the equipment will return to assign to NOISE FREQ. the default value.
11/2008
Premium
divides the bandwidth of the channel (CHANNEL
Premium
takes by default NOISE FREQ.
VERY IMPORTANT
Premium
tunes it at its
Page 25