3 Technical data
Right of technical changes reserved.
NOTE
All values apply to individual rod-like metal objects positioned at right angles to the direction of movement of the
detector and when the surface of the concrete is flat and smooth with no external interference factors. Detection range
and accuracy is reduced when measurements are taken on brickwork.
PS 35
Detection range for locating ferrous metals in concrete
(individual rebars)
Detection range for locating non-ferrous metals (copper
and aluminium pipes)
Depth measurement range for individual rebars
Accuracy of depth measurement (accurate measure-
ment mode)*
Localization accuracy
Minimum distance between objects
Power source
Battery life at 20 °C
Operating temperature range
Automatic cut-out
Storage temperature range (dry)
Relative air humidity
Protection class
Weight (including batteries)
Dimensions (L x W x H)
NOTE
* Applies to concrete with typical aggregate and reinforcement content.
Measuring units
mm
In
in ¹⁄₈
>∅ 8 mm (≧ # 3): 5...120 mm (¼ in ...4¾ in)
∅ 6...8 mm: 5...100 mm (¼ in ... 4 in)
Diameter Min. 10 mm (½ in), Wall thickness Min. 2 mm
(³/₃₂ in): 5...80 mm (¼ in ...3¹/₈ in)
>∅ 8 mm (≧ # 3): 5...120 mm (¼...4¾ in)
∅ 6...8 mm: 5...100 mm (¼ ... 4 in)
Depth range 5...60 mm (¼ in ... 2²/₃ in): ±3 mm (±¹/₈ in)
Depth range 60...80 mm (2²/₃ in ... 3¹/₈ in): ±5 mm (±¼
in)
Depth range 80...100 mm (3¹/₈ ... 4 in): ±7 mm (±⁹/₃₂ in)
Depth range 100...120 mm (4 in ... 4³/₄ in): ±11 mm
(±⁷/₁₆ in)
±10 mm (±½ in)
Depth range 5...55 mm (¼ in ...2¹/₈ in): 55 mm (2¹/₈ in)
Depth range ≥ 55 mm (2¹/₈ in): Distance/depth factor
>1.5
4x1.5V (AAA) LR03 alkaline batteries
8 h
-15...+50°C (5° F ... 122° F)
5 min
-25...+63°C (-13° F ... 145° F)
95%
IP 54 (protection against dust and water spray)
450 g (1 lb)
237 mm x 104 mm x 47 mm (9.4 in x 4 in x 2 in)
Dimensions
Millimeters
Inches
¹⁄₈ fraction
en
17