Virutex CE24E Manual De Instrucciones página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 3
7. CHANGING THE TRANSMISSION BELT
Unscrew screws F (Fig. 3) and remove protection E.
Replace the worn belt with a VIRUTEX original spare,
taking care to fit it correctly into the pulley cogs,
never forcing it. (Fig. 4).
8. MAINTENANCE OF THE
BRUSHES AND COLLECTOR
Disconnect from the mains before ca-
rrying out any maintenance operations.
The brushes must be replaced when they reach a
minimum length of 5 mm (Fig. 5).
Unscrew screws H and remove the ventilation lid. Slip
the brush-holder out of its guide. Replace the brushes
with original VIRUTEX ones, sliding them gently into
the brush-holder. Fit this back into its guide and
screw the lid back in place. It is recommended that
the appliance be left idling for 15 minutes to run
the brushes in.
If the collector is burned or uneven it should be
repaired by a VIRUTEX service agent.
Always keep the lead and plug in good working
condition.
9. ASPIRATION NOZZLE ASSEMBLY
To fit the nozzle, proceed as show in (Fig. 6). The 2.25
m standard aspiration coupling tube (Ref. 6446073)
may be connected to the aspiration nozzle and that
tube can be connected to the AS182K, AS282K
vacuum unit.
Do not use the brush with the aspiration
nozzle fitted without first connecting
up the machine to a vacuum unit, since
otherwise chips may block the nozzle.
10. LATERAL FENCE
For planing operations following the edge of the
wood. Adjusted by means of knob G (see Fig. 1).
11. OPTIONAL ACCESSORIES AND TOOLS
11.1 TOOLS
3540118 - Set of reversible straight MD blades CE24E/
CE35E (Included with equipment)
3531019 - Set of reversible straight AR blades
CE24E/CE35E
3599101 - Set of standard blades
11.2 ADJUSTABLE LATERAL FENCE 2200018
Features: for different degrees of chamfer.
Assembly: screw the two screws J, incorporated in
the try square, into the holes which are on the same
side of the plane as the belt guard (Fig. 3).
Adjustment: loosen knob K and, using knob M, shift
the try square sideways.
Adjust the degrees of chamfer by means of wing
nuts L (Fig. 3)
12. NOISE AND VIBRATION LEVEL
The noise and vibration levels of this device have
been measured in accordance with European stan-
dard EN 60745-2-14 and EN 60745-1 and serve as
a basis for comparison with other machines with
similar applications.
The indicated vibration level has been determined
for the device's main applications and may be used
as an initial value for evaluating the risk presented
by exposure to vibrations. However, vibrations
may reach levels that are quite different from the
declared value under other application conditions,
with other tools or with insufficient maintenance
of the electrical device or its accessories, reaching a
much higher value as a result of the work cycle or
the manner in which the electrical device is used.
Therefore, it is necessary to establish safety measures
to protect the user from the effects of vibrations,
such as maintaining both the device and its tools
in perfect condition and organising the duration
of work cycles (such as operating times when the
machine is subjected to loads, and operating times
when working with no-load, in effect, not in use, as
reducing the latter may have a considerable effect
upon the overall exposure value).
13. WARANTY
All VIRUTEX power tools are guaranteed for 12 months
from the date of purchase, excluding any damage
which is a result of incorrect use or of natural wear and
tear on the machine. All repairs should be carried out
by the official VIRUTEX technical assistance service.
14. RECYCLING ELECTRICAL EQUIPMENT
Never dispose of electrical equipment with domestic
waste. Recycle equipment, accessories and packaging
in ways that minimise any adverse effect on the
environment. Comply with the current regulations
in your country.