Setting up the machine
5.4 Performing a stripping test
Each time the material to be processed has been changed,
a stripping test must be conducted.
► Switch on the mains switch.
► Switch to "Stripping mode" operating mode on the touch
display (see section 6.6).
► Insert a wire for stripping.
► Check the result:
– Is all the stranded wire undamaged?
– Has stripping been performed straight and evenly?
► Use an uncrimped wire-end ferrule to check whether the
stripping length fits and whether the selected combina-
tion of wire and ferrule are a perfect match. If necessary,
switch to S-ferrules (with a larger plastic plastic collar;
see section 2.2).
5.5 Setting the cutting depth
Depending on hardness and thickness, adjusting the cut-
ting depth for the stripping may be required. To do this, the
blade distance must be modified by shifting the two eccen-
trics.
► To get to both eccentrics, press the tool unit backwards
and swing it to the right.
Figure 5.8 Stripping unit
► Release both eccentric screws (1).
► To reduce the cutting depth, move both eccentrics to-
wards "+" (larger blade spacing).
► To increase the cutting depth, move both eccentrics to-
wards "–" (shorter blade spacing).
► Re-apply both eccentrics screws.
34
The configuration of both eccentrics must match
one another.
5.6 Removing the wire-end ferrule reel
► Switch the machine off.
► Place the fixing pin with the large diameter into the top
opening of the transport unit.
Figure 5.9 Releasing the wire-end ferrule belt
► Push the fixing pin in the guide right to the top.
► Pull the wire-end ferrule belt out of the transport unit.
► Take the wire-end ferrule reel out of the holder.
► Remove the fixing pin.
1