Recalling Saved Data On Instrumental Memory; How To Delete Data In Memory; Configuration Menu - XS Instruments 8+Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Press
key to return in measurement mode and activate MEAS Cond screen. In the upper band you
can find icons
-print – and
Connect the printer to the RS232 port.
When you want to print the value, press
Note: For the first printed value of each series, the header selected in P5.3 is also printed.

• Recalling saved data on instrumental memory

In measurement mode of the parameter of interest press
parameter.
Using
and
keys scroll through the various pages of data.
Press
key to exit and return in measurement mode.
Note: The first value of a series always has a progressive number "1" and is identified by an orange icon.

• How to delete data in memory

To delete data in instrumental memory, enter into P5.4 setup menu and select Yes.
Note: The stored data is kept even if accidentally the power supply fails.
IMPORTANT: The factory reset of the pH, Ion and Cond parameters does not delete the stored data.

Configuration menu

In measurement mode press "
Use
and
keys to scroll until "Configuration" menu and press
Use
and
keys to move and then select the program you want to edit.
The table below shows the structure of the setup menu for the Configuration parameter, for each program
there are the options that the user can choose and the default value.
Program
Description
P6.1*
Sample ID
P6.2*
User ID
P6.3*
Company name
P6.4*
pH Sensor ID
P6.5*
Cond Sensor ID
P6.6
Password
P6.7*
Display information
P6.8
Reading with HOLD
P6.9
Date format
P6.10
Date setting
P6.11
Time setting
P6.12
Temperature unit option
P6.13
Set Language
* function available only for 80+ Series
P6.1 / P6.2 / P6.3 / P6.4 / P6.5 (function available only for 80+ Series)
To use these programs, connect the external keyboard to the USB port identified as "keyboard" (see
paragraph "Input / output connection"). Use only the keyboard supplied by the manufacturer, for
information contact the local distributor. The symbol
established. Access these programs to assign an alphanumeric identifier that will appear on the display in
complete mode (P6.7) and during printing Complete and GLP (P5.3):
P6.1 Sample ID: name of the sample; max 8 characters, appears on display along with the
in printing for each measure in all formats.
UM Serie 880 EN rev.2 30.07.2020
- manual saving.
key.
MENU" key to enter into SETUP menu.
Options
-
-
-
-
-
-
Simple - Complete
YES – NO
dd/mm/yyyy – mm/dd/yyyy – yyyy/mm/dd
-
-
°C - °F
Eng – Ita – Deu – Esp – Fra - Cze
indicates that the connection has been successfully
31
to display the data stored for that specific
key to confirm.
Factory default
dd/mm/yyyy
EN
None
None
None
None
None
None
Simple
NO
-
-
°C
English
icon and

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

80+seriePh8+dhsPc8+dhsPh80+dhsPc80+dhsCond8+ ... Mostrar todo

Tabla de contenido