Miele PW 6101 Instrucciones De Montaje página 5

Ocultar thumbs Ver también para PW 6101:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
Produktgruppe 512
5 von 32
Danger!
Correct earthing function can be deactivated if casing parts are incorrectly assembled.
Correct earthing function must be ensured when refitting the casing.
Carry out appropriate electrical safety checks.
Danger!
During fitting, all accessible conductive parts that are not connected to the earth must not have any link to earth (strengthened double
insulation).
To confirm this, insulation resistance and touch current measurements must be carried out.
Note
The kit, Mat. no. 06256860, contains the following:
1 flow meter
1 adapter for water intake
2 seals 3/4" 16 x 23.8 x 1.5
Various cable holders 98 x 2.5
1 cable through-feed M12 x 1.5
1 wiring diagram: Multifunction module 07 MF07 PW Flügelradzähler (flow meter)
1 wiring diagram: PW 6107 - 6207 module 7
These fitting instructions - Flow meter FRZ01, Mat. no. 06258812.
List of illustrations:
Fig. 1: Connection of flow meter to 3/4" stopcock
Fig. 2: Connection of water intake hose or Y-piece to flow meter
Note
PW 6107, PW 6137, PW 6167, PW 6207
The flow meter can only be fitted if the "MF07 10-20 multifunction module PWxx7" is already fitted and registered in the machine.
Register the module 7.
Via Service level
Main menu
button
Activate disk symbol to save the setting.
Note
PW 6101, PW 6131, PW 6161, PW 6201
The flow meter can only be fitted if the "MF07 multifunction module" is already fitted and registered in the machine.
Register the module 7.
Via the service mode depending on the software ID, e.g. Service level main menu
MFM with coding 7
Activate disk symbol to save the setting.
Or Service level main menu
Activate disk symbol to save the setting.
Note
PW 6163, PW 6243, PW 6323
The flow meter can only be fitted if the kit "BSF-RU flow meter clean/soiled side" is already fitted in the machine.
Note
During fitting, the adapter must be fitted as a damper between the stopcock and flow meter. Take note of the arrow marked on the flow
meter showing the correct direction of flow. Use the correct seals appropriate for the pipe diameter only. In this way water can flow freely
without added turbulence through the measuring area. Correct flow measurement can only be achieved if these instructions are complied
with.
15.08.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Service settings
Module registration
Service settings
Module registration
Umbau- und Montageanweisung
EZL with coding 7
Module registration?
Service settings
EZL with coding 7
Module registration?
M.-Nr. 06258812
OK
Module registration
OK button
loading