CONTROL UNIT PERGOLA TILT IO
2. 4. DESCRIPTION OF CIRCUIT BOARD INDICATOR LIGHTS
The LED flashes every 4 seconds:
Circuit board waiting.
The LED flashes rapidly:
Command in progress.
The red LED light remains illuminated for 5 seconds:
Current consumption threshold has been exceeded or
circuit board has heated up too much during an output
command.
The red LED flashes:
drive synchronisation fault.
The orange LED remains illuminated for several
seconds:
Backing-up the memory.
The orange LED flashes rapidly:
Movement of a drive not permitted by a sensor action .
The orange LED remains illuminated: Wind threshold
has been exceeded.
The orange LED flashes rapidly: protection still in
progress for 15 minutes after the threshold last being
exceeded.
The orange LED remains illuminated: The rain threshold
has been exceeded.
The orange LED flashes rapidly: protection still in
progress for 15 minutes after the threshold last being
exceeded.
The orange LED remains illuminated: the ice threshold
has been exceeded.
The orange LED flashes rapidly: protection still in
progress for 15 minutes after the latest threshold is
exceeded.
Snow: The rain and temperature information is combined.
-
S2 +
(1) Correct operation of the sensors will depend on the maintenance and installation conditions outside
next to the pergola. Read the sensor instructions before installing them.
(2) The sensors shall remain visible even if the sensors have been deactivated.
-
S2 +
Copyright
2017 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
Status
Fault
Wind
(1)
-
+
OUTPUT Vdc
Rain
(1) (2)
-
+
S1
Temperature
(1) (2)
OUTPUT Vdc
POWER SUPPLY
-
+
-
+
OUTPUT Vdc
OUTPUT Vdc
-
+
POWER SUPPLY
-
+
-
+
-
+
-
S2 +
S1
OUTPUT Vdc
OUTPUT Vdc
-
S2 +
EN