2. 3. DESCRIPTION AND CONNECTIONS

Switch 1
ON
Drive with coder sensor
OFF
Drive without coder sensor
Switch 2
(only if switch 1 is set to ON)
ON
Activates synchronisation S1 and S2
OFF
Deactivates synchronisation S1 and S2
Switch 3
ON
5.5 A max. per output
OFF
3 A max. per output
Switch 4
ON
Activates the temperature sensor
OFF
Deactivates the temperature sensor
Switch 5
ON
Closing in the event of wind
OFF
Opening in the event of wind
Power Supply Input
A
-
24 Vdc power supply input (SELV)
B
+
Drive output 1
C
-
24 Vdc - 3A/5.5A drive: Maximum
current according to switch 3
D
+
Drive output 2
E
-
24 Vdc - 3A/5.5A drive: Maximum
current according to switch 3
F
+
Drive coder input
(Switch 1 = ON)
G
Coder input (ILS or HALL) drive 1
H
Not used
I
-
Power Supply Output:
J
24 Vdc/- 300 mA
+
K
Not used
L
Coder input (ILS or HALL) drive 2
M
-
Power Supply Output:
N
24 Vdc/- 300 mA
+
Rain Sensor
O
Contact
Dry contact input
L
Common
Q
-
Power supply output:
R
24 Vdc/- 300 mA
+
External aerial
S
Signal Conductor
T
GND
Shielding braid
20
R
Q
O P
Output
-
+
Power supply
OUTPUT Vdc
Rain sensor
-
+
OUTPUT Vdc
C
D
-
+
S1
-
+
-
+
-
+
OUTPUT Vdc
S1
OUTPUT Vdc
C
D
G H I J
-
+
S1
Copyright
2017 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
CONTROL UNIT PERGOLA TILT IO
S T
OFF
OFF
OFF
OFF
OFF
A
B
POWER SUPPLY
-
+
-
+
OUTPUT Vdc
OUTPUT Vdc
POWER SUPPLY
-
+
OUTPUT Vdc
POWER SUPPLY
M
N
K
L
-
+
-
+
OUTPUT Vdc
OUTPUT Vdc
External aerial
PROG button.
Switch 1
ON
Switch 2
ON
Switch 3
ON
Switch 4
ON
Switch 5
ON
Power supply
input
E
F
Drive output S2
-
S2 +
-
S2 +
Drive output S1
E
F
-
S2 +
Drive output S2
HALL PNP
HALL PNP