Whirlpool CGT9100GQ Instrucciones De Instalación página 24

Lavadora/secadora comerciales apiladas a gas o eléctricas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ELECTRIC DRYER ELECTRICAL CONNECTIONS
Power supply cord,
4-wire connection:
IMPORTANT: A 4-wire connection is
required where local codes do not permit
the use of 3-wire connections.
B
A
C
D
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. 3/4" (19 mm) UL Listed strain relief
G. Ring terminals
1. Remove center terminal block screw.
2. Remove neutral ground wire from
external ground conductor screw.
Connect neutral ground wire and
the neutral wire (white or center wire)
of power supply cord under center
terminal block screw. Tighten screw.
A
B
A. External ground conductor screw – Dotted line shows
position of NEUTRAL ground wire before being moved
to center terminal block screw.
B. Center terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL Listed strain relief
24
F
E
C
D
E
3. Connect ground wire (green or bare) of power supply
cord to external ground conductor screw. Tighten screw.
A
B
C
G
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. 3/4" (19 mm) UL Listed strain relief
D. Center terminal block screw
E. Neutral ground wire
F. Neutral wire (white or center wire)
4. Connect the other wires to outer terminal block screws.
Tighten screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer
rear panel. Secure cover with hold-down screw.
7. You have completed your electrical connection.
D
E
F

Hide quick links:

Tabla de contenido
loading

Tabla de contenido