Sperian MILLER NBR 14628 Instrucciones De Uso página 4

Dispositivo anticaídas retráctil
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ATTENTION:
TO OTHER POINTS THAN THOSE INTENDED FOR THIS SYSTEM.
ON THE ADJUSTMENT ELEMENTS OR ON THE ACCESSORY HOLDER.
THE "D" BACK ANCHORAGE POINT OF THE HARNESS IS THAT WHICH WILL ALLOW,
IN THE CASE OF A FALL, THE BEST POSITIONING (Picture 1.4).
Limits of use:
► Maximum human load : 140.6 kg (Picture 1.5)
► Temperature of use : from - 30°c to + 50°c (Picture 1.6)
► Must always be placed above the user (Picture 1.7)
► Limit of pendular movement inferior to 30° (Picture 1.8)
► Can not stop a sinking (pulverulents or muddy products) (Picture 1.9)
Precautions of use:
► Check that the height of the anchorage point above the work space is compatible with the
capacity of the fall arrester and that sufficient clearance exists, which is compatible with
the characteristics of the device in the case of a fall.
► Check that during use, the cable or the webbing does not get wound around an arm or a leg.
► Never try to modify or to repair PPE; Only the manufacturer or a certified maintenance
centre is authorised to repair it.
► Never connect more than one person to the fall arrester.
► Never block the winding out of the cable.
► The cable or the strap must always be tensed. In case of "slack", the equipment must be
checked by the manufacturer.
► Lateral movements mustn't exceed one third of the distance ground / working surface.
► Make your movements on a normal walking speed. Accelerations, climbs and others en-
gage the clamping system of the equipment.
This equipment is designed for vertical use. If your cable drum has been designed for a special use
(horizontal or inclined) you must follow the recommendations of the additional specific instruction.
If the retractable lifeline includes a retrieval mechanism for emergeny rescue (i.e., MightEvac Self-
Retracting Lifeline with Emergency Retrieval Hoist), you must also read and follow all warnings and
instructions in the supplemental instructions for use (I278).
AIR CLEARANCE
Before using a cable drum, check for a minimum space clearance below the user's feet as nec-
essary, to prevent any collision with the structure or the ground.
With a weight of 140.6 kg in a normal use (cable drum above the head), the air clearance D is
the stopping distance H + an additional distance A + 1M. A is function of the length of cable out L
and the angle formed by the cable (or D, H, A and L in m and in °) (Picture 3).
ANCHORAGE POINT
Choose, if possible, an anchorage point, that is to say elements fixed to last, to a structure (wall,
post...).
Check that the anchorage point:
► has a resistance superior to 22 KN (Picture 1.10)
► is situated above the operator (Picture 1.7)
► vertical to the work surface : (angle maxi ±30°).
► Suits at best the anchoring system
► Does not present sharp edge.
DO NOT ATTACH THE CABLE OF THE FALL ARRESTER
DO NOT ATTACH IT DIRECTLY TO THE WEBBING,
E n gli sh