siGGen – Signal Generator
This command selects/reports of the signal generator activation.
Command
Form: DEVICE siGGen [Channel Group Type Amplitude Frequency]
argument
Type
Channel
Channel
Group
Group
Type
unsigned integer
Amplitude
Signed Float
Frequency
unsigned Float
siGGenen – Signal Generator Enable
This command selects/reports of the signal generator activation.
Command
Form: DEVICE siGGenen [Value]
argument
Type
Value
unsigned integer
siGGensWeep – Signal Generator Sweep
This command starts the signal generator with a tone and does a sweep. if Repeat is 0, the signal generator will
turn off after the sweep. if Repeat is 1, the signal generator will turn off after signal generator timeout. To stop
the sweep, send a SiGGenen command with a 0. during the sweep, the box will send out updated SiGGen
commands.
Command
Form:
DEVICE siGGensWeep <Channel> <Group> <Amplitude> <Start Frequency> <end Frequency>
<increment Frequency> <rate> <repeat>
argument
Type
Channel
Channel
Group
Group
Amplitude
Signed Float
Start
unsigned Float
Frequency
end
unsigned Float
Frequency
increment
unsigned Float
Frequency
rate
unsigned integer
repeat
unsigned integer
size
values
1
See Groups and channels
(null to query in text)
1
1, 3, 7 (i, m, l)
2
1 = pink noise
2 = White noise
3 = Tone
4
-60.00 – 20.00
4
Type 1 – 2
0 (null in text)
Type 3
20.00 – 20000.00
size
values
4
0 = off
1 = on
2 = Toggle
(null to query in text)
size
values
1
See Groups and channels
1
1, 3, 7 (i, m, l)
2
-60.00 – 20.00
4
20.00 – 20000.00
4
20.00 – 20000.00 (must be greater than the
start)
4
1.00 – 20000.00
2
10 – 2000 ms
2
0 = repeat off
1 = repeat on
Units
dB
Hz
Units
Units
dB
Hz
Hz
Hz
Hz
Appendix A: Serial Commands