SWITCH 1: Off
Automatic closing on
SWITCH 1: On
Automatic closing off
SWITCH 2: Off
Warning time off
SWITCH 2: On
Warning time on
SWITCH 3: Off
Temporary pause off
SWITCH 3: On
Temporary pause on
SWITCH 4: Off
Pause time with safety device off
SWITCH 4: On
Enable pause time with safety device on
SWITCH 5: Off
Courtesy light on
SWITCH 5: On
Flashing ligth on
SWITCH 6: Off
}
Standard pass-by-pass operation
SWITCH 7: Off
(open - close - open)
SWITCH 8: Off
SWITCH 6: On
}
Mode 2 pass-by-pass operation
SWITCH 7: Off
(open - pause - close - open)
SWITCH 8: Off
4
SWITCH 6: On
}
Mode 3 pass-by-pass operation
SWITCH 7: On
(open - stop - close - open)
SWITCH 8: Off
SWITCH 6: Off
}
SWITCH 7: Off
Shared property operation
SWITCH 8: On
SWITCH 9: Off
Gate open without limit switc warning light
SWITCH 9: On
Gate open with limit switch warning lite
SWITCH 10: Off
Temporary stop on
SWITCH 10: On
Temporary stop off
SWITCH 11: Off
Water hammer off
SWITCH 11: On
Water hammer on
N.B. Before switching on the power supply to the control unit, check that the 220V/