10. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
Air leak from the valve of the
The motor and/or the
compressor overheat
After an attempt to start the
compressor, it stops due to
tripping of the thermal cutout
caused by forcing of the
During operation, the
compressor stops for no
When operating, the
compressor vibrates and
the motor emits an irregular
does not restart although the
Irregular presence of oil in the
Leaking of condensate from
Any other type of operation must be carried out by authorized Service Centers, requesting original parts.
Tampering with the machine may impair its safety and in any case make the warranty null and void.
CAUSE
Check valve does not perform its
function correctly due to wear or dirt
Rilsan hose not inserted correctly in
Tripping of the thermal cutout of the
Single-phase motors:
3-phase motors:
power supply is missing due probably
23
REMEDY
Clean the pad inside the check valve
Insert the Rilsan hose correctly inside the
Check belt tension
Release the compressor head by using the
Check that the mains voltage matches that
Check level, top up and if necessary change
section 1, paragraph titled "Tripping of the
thermal cutout
Check the fuses inside the electric panel
or the electric box and if necessary replace
G