Technical Specifications - Velleman DCM330 Manual Del Usuario

Pinza amperimétrica digital
Ocultar thumbs Ver también para DCM330:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21

6. Technical Specifications

Clamp Size
Diode Test Current
Continuity Check
Low Battery Indication
Overrange Indication
Measurement Rate
Input Impedance
Display
AC Current Bandwidth
AC Voltage Bandwidth
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Over-voltage
Auto Power-Off
Power Supply
Dimensions
Weight
Accessories
Function
AC Current
DC Voltage
V. 03 – 14/06/2016
DCM330
opening 23mm (14/16")
0.3mA typical; open circuit voltage 1.5VDC
threshold < 120 ; test current < 1mA
" " is displayed
"" is displayed
2 per second, nominal
7.8M
(V DC and AC)
3 ½ digits (2,000 counts) LCD
50/60Hz (AAC)
50/400Hz (VAC)
-10°C ~ 50°C (14°F ~ 122°F)
-30°C ~ 60°C (-14°F ~ 140°F)
90% (0°C ~ 30°C or 32°F ~ 86°F)
75% (30°C ~ 40°C or 86°F ~ 104°F)
45% (40°C ~ 50°C or 104°F ~ 122°F)
operating: 3,000m
storage: 10,000m
category III 600V
after approx. 15 min
2 x 1.5V AAA batteries (incl.)
205 x 70 x 37mm
210g with battery
manual, test leads, batteries, carrying bag
Range
2.000 AAC
20.00 AAC
200.0 AAC
400 AAC
200.0 mVDC
2.000 VDC
20.00 VDC
200.0 VDC
600 VDC
± (2.5% of rdg + 10
± (2.5% of rdg + 4 digits)
± (3.0% of rdg + 4 digits)
± (0.5% of rdg + 510
± (1.2% of rdg + 3 digits)
± (1.5% of rdg + 3 digits)
7
Accuracy
digits)
digits)
©Velleman nv
Tabla de contenido
loading

Tabla de contenido