Transport
4. Rinse helmet shell and visors with clear water and wipe dry.
5. Apply anti-fogging spray kp-Comfort to visors if needed.
NOTICE
i
i
The visors can also be cleaned with alcohol-free glass
cleaner or kp-Comfort.
When the internal helmet components must be disinfected:
1. Prepare a disinfection bath of water and a disinfectant.
2. Place all parts to be disinfected into the disinfection bath
(duration: 15 minutes).
3. Rinse all parts thoroughly under running water.
4. Allow all parts to air-dry or dry in the drying cabinet
(temperature: max. 60 °C). Keep away from direct sunlight.
5.2.2
Visors with coating
1. Clean visors with anti-scratch or gold coating with
lukewarm soapy water or water only, then rinse with clear
water and wipe dry.
2. Clean visors with anti-fog coating with lukewarm water only
and let them dry in the air.
5.3
Maintenance work
The following maintenance work is normally not carried out by
the fireman, but by service personnel. They are therefore
described in the Technical manual:
Replacing a comfort net or Comfort Pad
Replacing the harness
Replacing the face protector
Replacing the eye protector/spectacles
Replacing the internal helmet components
Replacing the function plate
Replacing the front cover
Replacing the neck guard holder
Replacing the O-rings
Replacing the nose pad
6
Transport
The fire helmet may be carried in a helmet bag or tote. If the
fire helmet is packed in a polybag or wrapped in a sufficient
amount of wrapping paper, it may be transported in a box as
well. All attached components may remain attached to the fire
helmet during transport. The visors should be open.
7
Storage
Store the fire helmet cool and dry in a safe place. Avoid
exposure to direct sunlight during storage in order to prevent
any possible long term damage to the coating due to ultraviolet
radiation (especially in case of fluorescent paint).
Store visors in a clean, dry area out of direct sunlight and high
humidity.
As part of the original packaging, the visors are wrapped in a
protective film. This film should be left as is for storage. After
removal of the protective film, we recommend that you store
the visor in its fully-mounted position on the fire helmet.
Never store close to aggressive substances (e. g. solvents,
fuels). Storage temperature of 0 °C to 45 °C at normal ambient
pressure and a relative humidity up to 90 %.
20
8
Disposal
8.1
Life span
Check serviceability after each use (see Section 4.5 on
Page 19). The life span of the helmet and the visors depends
on the following factors:
Materials used
Environment in which the helmet is used and stored
Type of strain
Used as intended
Compliance with maintenance specifications
Further information may be obtained from Dräger.
8.2
Disposal information
Dispose of fire helmet and visor according to national rules and
regulations.
9
Technical data
9.1
Fire helmets
Helmet shell material
Weight
Storage temperature
9.2
Visors
Optical class of the visors
The gold visors (R79262, R79156, R79465, R79373) have
also achieved the following filter classes:
Protection against ultra-violet light: Class 2-4
Protection against infrared light: Class 4-4
Welding protection filter: Class 4
Fibreglass-reinforced,
thermoplastic (PA-GF)
HPS 7000 Basic H1:
1380 g (±5 %)
HPS 7000 Standard H1:
1480 g (±5 %)
HPS 7000 PRO H1:
1580 g (±5 %)
HPS 7000 Basic H2:
1680 g (±5 %)
HPS 7000 Standard H2:
1780 g (±5 %)
HPS 7000 PRO H2:
1880 g (±5 %)
0 °C to 45 °C
1 or 2
(depending on the visor
version)
Dräger HPS 7000