THERMOBILE IMA Serie Manual Del Usuario página 23

Ocultar thumbs Ver también para IMA Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
ENGLISH
Fault
The burner starts,
27
but no flame is
built.
The burner starts
28
badly (pulsation).
29
The heater burns
30
at short intervals.
31
The burner
32
produces soot.
The main fan
33
does not start.
The burner starts,
34
the flame is built,
but the burner
stops.
The heater
35
cannot be
stopped.
The heater stops
36
completely.
The heater stops
37
burning. The
reset button is lit.
38
39
The heater
40
produces white
smoke.
The heater uses
41
too much fuel.
42
Record the maintenance details in table A in the
appendix at the back of this book.
IMA
IMA
Cause
The ignition transformer is
defective.
The fresh air supply is not
sufficient.
The burner chamber or heat
exchanger has problems.
The thermostat is set incorrectly
(burner thermostat function).
The burner relay has a failure.
The burner relay is defective.
The magnetic valve is dirty or
defective.
There is an overheating problem
inside the heater.
The suction line or main fuel filter
has an air leak.
The protection grill for the air
intake is dirty or blocked.
The heat exchanger is clogged.
The fuel system has air.
The nozzle is too big or the wrong
type is used.
The pump pressure is too high.
40.019.003 - rev 09 - 2018
40.019.003 - rev. 06 - 2011
Solution
Test the insulation in relation to
the burner.
Replace the ignition transformer if
necessary.
Open a door or a window.
See faults: 8, 14, 15, 16, 17, 18,
19, 20, 21, 22, 24, 25, 27.
Use a fresh air connection for the
burner.
Clean, repair or replace the
burner chamber and heat
exchanger, if necessary.
Set the burner thermostat
according to the specifications of
the manufacturer.
See faults: 3, 12, 13, 30.
See faults: 15, 16, 17, 18, 25, 26,
27, 29.
See faults: 1, 8, 9, 10, 11.
See faults: 3, 16, 20, 24, 28.
Replace the burner relay.
Clean or replace the magnetic
valve.
Reset the thermostat by pressing
the U key for two seconds (Fig.
7).
Reset the burner with the reset
button (A) (Fig. 6).
Check and replace if necessary.
Clean the grill.
Clean the heat exchanger.
Check the fuel system.
Replace the nozzle with the
correct one.
Check the pump pressure.
English
Action
Dealer
User
User
Dealer
Dealer
Dealer
Dealer
User
User
User
User
User
User
User
Dealer
23
23
Tabla de contenido
loading

Este manual también es adecuado para:

Ima 61Ima 111Ima 150Ima 200

Tabla de contenido