OPERATION
Before starting the compressor, thoroughly read all
component instruction manuals, especially the engine
manual.
All lubricated compressor pumps discharge some condensed water
and oil with the compressed air. Install appropriate water/oil removal
equipment and controls as necessary for the intended application.
Failure to install appropriate water/oil removal
equipment may result in damage to machinery or
workpiece.
Drain liquid from tank daily.
Do not attach air tools to open end of the hose until
start-up is completed and unit checks OK.
START-UP
To ensure proper operation, unit must be on a
level surface.
1. Fill engine with oil and gasoline per instructions furnished with
engine.
2. Check oil sight glass to verify proper oil level.
3. Turn manual unloader lever up to a horizontal position to allow the
compressor pump to run without compressing air.
TO START GASOLINE ENGINE
1. Move the choke lever to the CHOKE position, turn the fuel lever ON,
and turn the engine stop switch to the ON position.
2. Pull start grip lightly until resistance is felt, and then pull briskly.
3. As the engine warms up, gradually move the choke lever to the open
position. See gas engine manual for more details.
4. Run the compressor unloaded for approximately 30 minutes to break
in the pump.
5. After approximately 30 minutes, move the unloader lever down to the
loaded position. The compressor will begin to pump air into the tank.
When maximum tank pressure is reached, the compressor
automatically unloads, bringing the engine to idle. The engine
remains at idle until tank pressure falls to a preset level. The engine
then accelerates and the compressor pumps additional air into the
tank.
Manual Unloader Lever in the
Unloaded Position
Figure 3 - Unloader Lever Unloaded
Manual Unloader Lever in
the Loaded Position
Figure 4 - Unloader Lever Loaded
8