Important - Craftsman 247.77466.1 Manual Del Operador

Ocultar thumbs Ver también para 247.77466.1:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

For Parts Call 606-678-9623 or 606-561-4983
For Parts Call 606-678-9623 or 606-561-4983
2. Disconnect the dislodger from the beam weld bracket by removing
the six hex screws. See Figure 3-4.
3. Disconnect the log cradle from the beam on the side of the control
valve. See Figure 3-5.
4. Lift and slide the cylinder up to the top of beam and into the weld
brackets.
5. Attach the dislodger over the wedge assembly and secure with
hardware, previously removed, to the weld brackets.
NOTE: Once the six hex screws are tightened, there may be a slight
gap between the dislodger and the weld brackets. This gap is normal.
6. Reattach the log cradle to the side of the beam with the control
valve, aligning the ends of the cradle with the beam flanges.
7. Roll log splitter off the bottom crate.
Preparing the Log Splitter
1. Lubricate the beam area (where the splitting wedge will slide) with
engine oil; do not use grease.
2. Remove vented reservoir dipstick, which is located in front of the
engine on top of the reservoir tank. See Figure 3-6.
IMPORTANT: The log splitter may have been shipped and primed
with hydraulic fluid in the reservoir tank. However, you MUST check
the fluid level before operating. If not filled, proceed with the following
steps:
3. Fill the reservoir tank with hydraulic fluid included with this unit (if
equipped) or approved fluids which include Dexron® III / Mercon®
III automatic transmission fluid, a 10 Weight AW hydraulic oil or
Pro-Mix™ AW-32 Hydraulic Oil.
4. Check fluid level using the dipstick. See Figure 3-6. Do not overfill.
5. Replace vented dipstick securely, tightening it until the top of the
threads are flush with top of the pipe.
6. Disconnect the spark plug and prime the pump by pulling the recoil
starter as far as it will go. Repeat approximately 10 times.
7. Reconnect the spark plug wire and start engine following instruc-
tions in the OPERATION section.
8. Use control handle to engage the wedge to the farthest extended
position. Then retract the wedge.
9. Refill tank as specified on the dipstick.
NOTE: Failure to refill the tank will void unit's warranty.
10. Extend and retract the wedge 12 complete cycles to remove
trapped air in the system (the system is "self-bleeding").
11. Refill reservoir within range marked on the dipstick.
WARNING: Much of the original fluid has been
drawn into the cylinder and hoses. Make certain
to refill the reservoir to prevent damage to the
hydraulic pump.
NOTE: Some fluid may overflow from the vent plug as the system
builds heat and the fluid expands and seeks a balanced level.
ASSEMBLY
www.mymowerparts.com
www.mymowerparts.com
Figure 3-4
Figure 3-5
Figure 3-


Capítulos

Tabla de contenido
loading

Tabla de contenido