PREPARING THE ICE MACHINE FOR STORAGE
14. Remove the top clamp from the vent tube, for easier
access for the air hose.
15. Apply air pressure (approximately 10 psi) to the end of
the vent tube which will purge the remainder of the
water from the drain pump and the drain line. (See
Figure 40).
16. Reinstall the vent tube and clamp to the back of the ice
machine and remove the winterization plug from the ice
bin and save it for future use.
Vent
tube
Remove
clamp
screw
Drain
Figure 40
line
To Restart the Ice Machine
1. Reconnect or turn on the water supply line.
2. Reconnect drain tubing if removed.
3. Plug in the power cord to a wall outlet and turn the ice
machine on, (refer to page 13 for turning the ice ma-
chine on and off).
4. Check the water inlet, drain lines, and fittings for any
water leaks.
5. Check drain pump operation by pouring approximately
two (2) quarts of water into the ice storage bin. The
drain pump should activate and discharge water.
Check for water leaks at all hose connections.