Volume setting

Transmission
This function defines the volume of the transmitting signal.
On the setting mode, press: 1 + 5 + 0 + 4 + * + volume + #.
Where:
Volume: is the transmission volume which varies from 0 to 15. The standard
volume is 1.
Example: ***99*222222#1504*10#. The volume will be 10.
Reception
This function defines the volume of the receiving signal.
On the setting mode, press: 1 + 5 + 0 + 5 + * + volume + #.
Where:
Volume: is the reception volume which varies from 0 to 7. The standard
volume is 5.
Example: ***99*222222#1505*3#. The volume will be 3.
Flash timer
This function defines the maximum time allowed for the flash on the TEL
port of the ITC 4000.
On the setting mode, press: 1 + 5 + 0 + 3 + * + time + #.
Where:
Time: 80 a 2000 ms. The standard time is 300 ms.
Example: ***99*222222#1503*100#. The flash time will be 100 ms.

Call timer

Dialed calls
This function defines the maximum time for calls made through the ITC 4000.
On the setting mode, press: 1 + 5 + 0 + 1 + * + HAB + * + time + #.
Where:
HAB:
0: disables function.
1: enables function.