LED screen
LED 1 is red and LED 4 is
green, battery pack does not
charge or operate correctly in
product
LED 1 is red
LED 4 is green
LED 1 is red and LED 2 is
green, battery pack does not
charge or operate correctly in
product
RED LED comes on, LED 2
is green and flashes during
charging or when the battery
pack is in the battery charger
RED LED flashes and LED 2
flashes green when the bat-
tery pack is installed.
Motor specifications
Motor type
Motor voltage
Motor power
Battery pack and battery charger specifications
Default battery pack type
Default battery charger type
Noise and vibration data
Equivalent vibration level at handles equipped with blower tubes (origi-
nal). See Note 1.
Sound power level, guaranteed (LWA). See Note 2.
Sound power level, measured. See Note 2.
451 - 002 - 20.11.2017
Possible faults
Internal fuse is blown
Irregular cell voltage
Battery pack is over-
charged
Battery pack failure
Internal battery tempa-
ture is too low or too
high for charging
Internal battery tempera-
ture is too low or too
high

TECHNICAL DATA

Possible steps
Speak to an approved service center.
Speak to an approved service center.
Remove the battery pack from the battery charger and in-
stall in the product. Operate the product. Battery charger
may be defective. Speak to an approved service center.
Remove battery pack from the product. Do not charge.
Battery pack is damaged and must be replaced. Speak to
an approved service center.
Move the battery charger and battery pack to a location
where the internal temperature of the battery pack can be
between 5°C (41°F) and 45°C (113°F).
The internal temperature in the battery must be between
-15°C (5°F) and 70°C (158°F). The environment tempera-
ture in the battery pack is too low or too high.
If the battery pack is too cold from the ambient envi-
ronment, move the battery pack and battery charger to
a warm environment.
If the battery pack is too hot, especially after operation,
move the battery pack and battery charger away from
the hot environment.
unit
V (DC)
W
2
m/s
dB(A)
dB(A)
Li 58GB (BHB58VPR)
Brushless
58
1200
Li 585.2A
Li 58V 2.5CGR
5.429
99
96
11