will be completed. If you wish to change the profile to a Minimum value
"MIN" repeat the operation described above, pressing the SEL key twice
(LED L4 will blink rapidly) rather than once. Repeat the procedure if you wish
to restore the initial configuration.
5. FORCE CLOSE (Selecting the Force profile in the Normal
Closing cycle):
The control unit allows you to define different operator Force profiles during
the Normal operating cycle in the Closing movement. In the factory set
configuration, operator Force during closing is set at the maximum level
"MAX" (i.e. identical to the setting selected using the SPEED trimmer with
LED L5 off); if you wish to change the profile to a medium level value "MED"
proceed as follows: use the SEL key to select blinking LED L5 and press the
SET key; at the same time LED L5 becomes steady on and programming
will be completed. If you wish to change the profile to a Minimum value
"MIN" repeat the operation described above, pressing the SEL key twice
(LED L5 will blink rapidly) rather than once. Repeat the procedure if you wish
to restore the initial configuration.
6. SLOWING OPEN (Selecting the Force profile in the Opening
Slowdown cycle):
The control unit allows you to define different operator Force profiles during
the Slowdown operating cycle in the Opening movement. In the factory set
configuration, operator Force during the opening slowdown stage is set at
the maximum level "MAX" (i.e. identical to the setting selected using the
SLOWING trimmer with LED L6 off); if you wish to change the profile to a
medium level value "MED" proceed as follows: use the SEL key to select
blinking LED L6 and press the SET key; at the same time LED L6 becomes
steady on and programming will be completed. If you wish to change the
profile to a Minimum value "MIN" repeat the operation described above,
pressing the SEL key twice (LED L6 will blink rapidly) rather than once.
Repeat the procedure if you wish to restore the initial configuration.
7. SLOWING CLOSE (Selecting the Force profile in the Closing
Slowdown cycle):
The control unit allows you to define different operator Force profiles during
the Slowdown operating cycle in the Closing movement. In the factory set
configuration, operator Force during the closing slowdown stage is set at
the maximum level "MAX" (i.e. identical to the setting selected using the
SLOWING trimmer with LED L7 off); if you wish to change the profile to a
medium level value "MED" proceed as follows: use the SEL key to select
blinking LED L7 and press the SET key; at the same time LED L7 becomes
steady on and programming will be completed. If you wish to change the
profile to a Minimum value "MIN" repeat the operation described above,
pressing the SEL key twice (LED L7 will blink rapidly) rather than once.
Repeat the procedure if you wish to restore the initial configuration.
EXTENDED MENU 1
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 1, proceed
as follows: select blinking LED LEV and press SET 1 times. The LED will
start blinking alternately 1 0 1 0 1 0. This means you have 30 seconds to
select the functions of Extended Menu 1 using the SEL and SET keys; once
an additional 30 seconds have elapsed, the control unit reverts to the main
menu.
L1
REMOTE PROGRAMMING
L2
PUSHBUTTONS PUL
L3
DO NOT USE
L4
FOTO TEST
L5
DO NOT USE
L6
DO NOT USE
L7
NC AS 8K2
LEV
MENU
1. REMOTE RADIO CONTROL PROGRAMMING:
The control unit allows the transmission code to be programmed remotely
without acting directly on the control unit SEL key.
Remote programming of a Radio remote control is performed as follows:
send the code of a previously saved remote continuously for more than 10
seconds; at the same time the control unit switches to programming mode
as described above for LED L1 in the main menu. If you wish to enable
the remote programming function, proceed as follows: ensure you have
enabled Extended Menu 1 (alternate blinking 1 0 1 0 1 0 of menu level
no. 8) and then use the SEL key to select blinking LED L1 and press the
SET key; LED L1 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
LED OFF
LED ON
OFF
ON
PUL=AP/CH
PUL=CH
DO NOT USE
DO NOT USE
OFF
ON
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
OFF
ON
1 FLASH
2. SELECT PUSHBUTTON PUL = OPEN/CLOSE OR CLOSE:
The control unit allows an NO Pushbutton (PUL CN2 input no. 11) to
be connected to operate the barrier in Open/Close mode. It is however
possible to use this input to connect an NO pushbutton operating in a
different manner. If you wish to enable the "Close only" function, proceed as
follows: ensure you have enabled Extended Menu 1 (alternate blinking 1 0 1
0 1 0 of menu level no. 8) and then use the SEL key to select blinking LED
L2 and press the SET key; LED L2 becomes steady on and the operation
will be completed. Repeat the procedure if you wish to restore the initial
configuration.
Nota: in Master/Slave applications, if the PUL "Close only" pushbutton has
been selected operation of the PED pushbutton will be enabled for both the
barriers rather than just the Master barrier.
3. NOT USED:
4. FOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled. If you wish
to enable the photocells test proceed as follows: ensure you have enabled
Extended Menu 1 (blinking 1 0 1 0 1 of LED LEV) and then use the SEL key
to select blinking LED L4 and press the SET key; LED L4 becomes steady
on and the operation will be completed. Repeat the procedure if you wish to
restore the previous configuration.
5. NOT USED:
6. NOT USED:
7. EMERGENCY STOP = 8k2:
The control unit allows the connection of an NC Emergency Stop
pushbutton (CN2 input no.8). However, this input can be converted to
an 8.2k-Ohm resistive input: ensure you have enabled Extended Menu 1
(alternate blinking 1 0 1 0 1 0 of menu level no. 8) and then use the SEL
key to select blinking LED L7 and press the SET key; LED L7 becomes
steady on and programming will be completed. A change in the value read
on the input causes the barrier to stop in the opening stage or reverse its
direction of movement in the closing stage. An additional barrier movement
command will be valid, provided the correct input value is restored, and the
control unit will in any case perform the barrier opening cycle. Repeat the
procedure if you wish to restore the initial configuration.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with the facility for direct
selection only from the main menu functions. If you want to enable the
functions described in Extended Menu 2, proceed as follows: select blinking
LED LEV and then press SET twice. The LED will start blinking alternately
1 1 0 1 1 0. This means you have 30 seconds to select the functions of
Extended Menu 2 using the SEL and SET keys; once an additional 30
seconds have elapsed, the control unit reverts to the main menu.
L1
EL. LOCK/CLAMP
L2
FLASH.OUT.CNTRL.
L3
ALWAYS CLOSE
L4
FOLLOW ME
L5
PRE-FLASH
L6
LED OUTPUT CONTROL
ENABLED>MOTO ON
L7
LED OUTPUT CONTROL
LEV
MENU
1. ELECTRIC LOCK / ARM CLAMP SELECTION:
The control unit is factory set with the Electric lock function enabled. If you
wish to enable the Arm clamp function, proceed as follows: ensure you
have enabled Extended Menu 2 (alternate blinking 1 1 0 1 1 0 1 1 0 of
menu level no. 8) and then use the SEL key to select blinking LED L1
and press the SET key; LED L1 becomes steady on and programming will
be completed. Repeat the procedure if you wish to restore the previous
configuration.
24Vdc 10W Electric Lock Operation: the command is activated at each
initial opening movement for a period of 2 seconds.
24Vdc 10W Arm Clamp Operation: the command is activated and
remains active until the manoeuvre has been completed, with return to the
initial position.
2. 24V 25W MAX FLASHING LIGHT OUTPUT CONTROL:
The control unit is factory set with an intermittent output for connection
to a 24V Flashing light (0.5 sec ON – 0.5 sec OFF). If you wish to enable
a fixed output, proceed as follows: ensure you have enabled Extended
Menu 2 (blinking 1 1 0 1 1 0 1 0 of LED LEV) and then use the SEL key to
select blinking LED L2 and press the SET key; LED L2 becomes steady on
and programming will be completed. Repeat the procedure if you wish to
restore the previous configuration.
COMUNELLO ®Copyright 2014 - All right reserved
LED OFF
LED ON
ELECTRIC LOCK.
ARM CLAMP
FLASHING LIGHT
PERMANENT
OFF
ON
OFF
ON
OFF
ON
NOT ALWAYS ENABLED
FLASHING LIGHT
PERMANENT
2 FLASHES
27