Mounting
the mounting
plate
Anchor
bolt holes
(Q65 ram)
Mounting
plate
Indoor
unit
Screw
Weight
directly m ounted to
the wall
1. To hook up the indoor unit, securely fit the mounting plate onto the wall by
screwing it in the upper and lower parts.
2. To mount the mounting plate on a concrete wall, with anchor bolts, drill the
anchor bolt holes as illustrated in the figure shown below.
3. Make sure the mounting plate is level.
When installing the mounting plate with a mounting screw, do not use the
anchor bolt holes• Otherwise, the unit may fatt down and result in personal
injury and property d amage.
Installation
plate
(Keep horizontal
direction
)
I L!
L--i
Anchorbo,t
..................
X
O
X
9Prlc_ei:.i115 ram) _
3/16 in. (5 ram) dia hole
or less
Iff
4
_J_7_
Mounting
.....
Q5/32 in. x 1 in.
_
(04
mm x
ram)
25
Clip anchor
(field supplied
parts)
iiiii_U_ii_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!_i!ii_i%_
i i
Failure to firmly install the unit may result in personal injury and property
damage if the unit falls.
• In case the unit is to be installed in a block, brick, concrete or similar type
walls, make 3/16 in. (5 mm) dia. holes in the wall.
• Insert clip anchors for appropriate mounting screws _7).
• Secure four corners and lower parts of the mounting plate with 4 to 6
mounting screws to install it.
Air inlet grille
Frontpanet
/
• Be sure to refer to the system wiring
diagram located inside the front panel.
• Check local electrical codes and also
any specific wiring instructions
or
limitations.
Fig. 1 Construction
Fig. 2
3-5/32
in. (80 mm)
Fixing
screw
Fig. 3 Wiring
Cord clamp
Terminal
_
/
cover
_
==!
Screw
Conduit
pipe
• Use stranded wire only.
• Wire type : minimum AWG14
all the air inlet grille on the indoor
unit
• When attaching the air inlet grille,
perform the same process as for
removal but in reverse order•
1. Open the air inlet grille upward.
2. Remove the screws securing the front panel.
3. Slightly open the lower part of the front panel, then pull the upper part of
the front panel toward you to remove it from the rear plate•
4. Insert the conduit pipe (according to local codes) into the pipe hole on
the walt.
5. Remove the conduit mount by loosening the fixing screw (Fig. 1)
6. Fix conduit pipe to conduit mount with the lock nut.
7. Pull out the connecting wire through the conduit pipe and process the
wire. (Fig. 2)
8. Take out the wire to the front and fix it to the terminal block•
Be careful not to mis-wire. (Fig. 3)
9. Firmly tighten the terminal screws to prevent them from loosening.
Tightening torque: 0.9 tbf.ft (1.2 N.m). After tightening, pull the wires
lightly to confirm that they do not move.
10. Secure the connecting wire with the cord clamp.
11. Fix the conduit mount back to the body by fixing a screw.
12. Fix the front panel, terminal cover and air inlet grille to the indoor unit.
drain hose form in g