When the flame is ignited, press ECO to lower the flame (two sound signals). Press ECO again to increase the flame
height (one sound signal).
ATTENTION!
In case the device temperature is too high, the flame will be automatically lowered (ECO) and the height
regulation blocked. If the temperature keeps increasing, the device will be turned off.
Press STOP to extinguish the flame (sound signal +
You can ignite the flame again when the device is cooled – the green diode READY (
The FAST START offers faster flame ignition (when the device is ready (
The function is enabled by default.
To disable FAST START, press and hold ECO on the control panel for 10 seconds (four sound signals). To enable the
function, press and hold ECO on the control panel for 10 seconds (two sound signals).
ERRORS
Some alarms are accompanied by a sound signal. Press START/STOP to mute.
Lp.
DIODES
1.
2.
3.
4.
5.
6.
7.
FUEL
Use only fuels consisting of
and viscous fuels or fuels of improper electric conductivity. The values must be compliant with those of FANOLA®.
Other fuels, such as dehydrated ethanol (i.e. consisting of more than 96,6% by volume ethanol) will cause a device error
and loss of the guarantee.
CLEANING –
Clean with a damp cloth and delicate detergents, only when the device is turned off and cooled.
SERVICE -
(keep the provided USB cable for servicing purposes) www.planikafires.com/service

FLAME HEIGHT REGULATION

FLAME EXTINGUISHING

FAST START

(contact the Service Department if the solution does not eliminate the error)
The device is being cooled. Wait for the green diode
The device run out of fuel while operating. The device is being cooled.
Wait for the red diode to turn off. Refill the tank.
An internal fuel spill occurred. Disconnect the pump. Wipe the visible liquid and wait
for min. 1 hour. Press and hold ECO on the control panel for 10 seconds. If the error is
If the error occurred during flame ignition, it means that the ignition time
has been exceeded. Press and hold ECO on the control panel for 10 seconds.
Device error. Press and hold ECO on the control panel for 10 seconds.
Tank overfilled. Contact the Service Department.
Room temperature too low (<10°C) or device error. Increase the room temperature.
Press and hold ECO on the control panel for 10 seconds. Wait for the green diode
Press and hold ECO on the control panel for 10 seconds.
86-96,6%
ethanol by volume. FANOLA® is the recommended fuel. Do not use gel, thick
Fuels consisting of 100% by volume ethanol will damage the device.
).
), the power consumption is 60 W higher).
SOLUTION
not eliminated, wait for min. 24 hours.