Macerator Toilet
Caution! Hazard of Flooding
If toilet is connected to ANY through-the-hull
fittings, ALL flexible hoses must be of marine
sanitation quality and must be secured to ANY
fittings (such as those at seacock, vented loop or
toilet) with two stainless steel, worm-drive hose
band clamps at each connection. Connections
MUST be checked frequently for integrity. Failure to
comply can result in flooding which can cause loss
of property and life.
Caution! Hazard of Flooding
If toilet rim is ever less than 8 in. (20 cm) above the
highest possible waterline at ANY time (during any
conditions of heel, load or trim) and is connected to
ANY through-the-hull fittings, properly positioned
ventilated (vented) loops MUST be installed in
intake* or discharge piping to prevent potential
back siphonage of sea water into the boat. Vented
loops must be equipped with integral check valve
that permits air into line to prevent siphoning.
Failure to do so can result in flooding which can
cause loss of property and life.
* if connected to raw water
Caution! Hazard of Flooding
If toilet uses sea water for flushing at ANY time, a
sea water pump controlled by an automatically
operating demand switch MUST NOT be installed.
If the onboard water valve or any plumbing
connections were to leak, the automatically
operated pump would start and could flood the
boat. Failure to comply can cause loss of property
and life.
Caution! Hazard of Flooding
Do not connect sea water flush toilet (models 7160,
7260) to an onboard pressurized water system.
Failure to comply can result in flooding which can
cause loss of property and life.
Caution!
Do not connect sea water flush toilet (models 7160,
7180) to an onboard potable water system. Failure
to comply could result in contamination of the
potable water supply.
EN
Caution! Hazard of Flooding
Before beginning any work on this product, be
sure that all electrical power to the unit has been
turned off and that seacocks are in the CLOSED or
OFF position. Failure to do so can result in flooding
which can cause loss of property and life.
Caution! Hazard of Shock or Fire
Always use recommended fuse, circuit breaker and
wire size. Failure to do so can result in fire that can
cause the loss of property and life.
Caution!
Discharge of sewage directly overboard is illegal
in some areas. Please check all local laws before
operating an overboard discharge sanitation system.
Caution! Hazard of Flooding
If the toilet uses fresh water for flushing and is
connected directly or indirectly to a shoreside
municipal water system at ANY time, shoreside
water connections MUST be disconnected if the
boat is unattended (even if boat is unattended for a
brief period). Failure to do so can result in flooding
which can cause loss of property and life.
Caution!
Overfilling the holding tank can create serious
damage to the sanitation system, such as rupturing
the holding tank and releasing tank contents into
the bilge. To prevent this possibility, Dometic
recommends using a "full" tank shut-down relay.
The "full" signal from the holding tank can be
generated by an optional Dometic DTM01C tank
monitor or DTM04 four-level tank monitor system.
General Safety Instructions
3