Beko OWAMAT 12 Instrucciones De Montaje página 22

Maintenance • Mantenimiento
Entretien • Manutenção
Prefilter
Main filter
Prefiltro
Filtro principal
Préfiltre
Filtre principal
Filtro prévio
Filtro principal
[gal]
12
0.7
14
1.8
15
4.9
16
9.6
* EWC 500 = European waste disposal key

Filter mat
Esterilla filtrant
Elément filtrant
esteira de filtro
[gal]
[inch]
1.6
4.7 x 1.97 x 1.18
2.9
4.7 x 1.97 x 1.18
5.4
7.58 x 3.15 x 1.18
10.6
7.58 x 3.15 x 1.18
Código de residuos europeo
Code européen de déchet
Europese afvalsleutel
Filter replacement
Weight
Order Ref.
This is necessary when
Peso
Referencia
- the water being discharged is too
Poids
No. de comm.
Peso
N°. de encom.
[lb]
- the filter is clogged (see 'Checking of
4.4
XV KT12 CF1
7.5
XV KT14 CF1
Note:
• Please observe the requirements of the
13.2
XV KT15 CF1
25.4
XV KT16 CF1
• Only use original OEKOSORB filter
• In the event of significant differences
• Remove plastic bag before filter instal-
Procedure
1. Place new OEKOSORB filter set near
2. Shut off condensate inlet
3. Open ÖWAMAT lid.
4. Get hold of the filter handles and slowly
5. Remove the handles and fit them onto
6. Put the drained filter set into the plastic
7. Insert the main filter into the filter
8. Insert the prefilter above the main
9. Open condensate inlet.
english
cloudy (see 'Waste water test')
level indicator')
Water Resources Act and other legal
regulations in your country pertaining to
the use and handling of filters. As part of
the operator's duty of care you should
always keep a spare OEKOSORB filter
set.
sets in order to ensure operational
reliability.
compared with the specifications of
the general technical approval, e.g. the
employment of non-original filters, the
approval no longer covers the usability
of the ÖWAMAT product. In such cases,
individual approval of the responsible
local authority will be required.
lation!
the unit. Keep the PE packaging of the
new set for putting in the old filters.
Open the service valve and let the
liquid drain off to below the level of the
cartridge.
pull the old prefilter and main filter out of
the container, turn filters counterclock-
wise by 45°, place on the top edge of
the container and allow to drain.
the new main filter.
bag and ensure correct disposal *.
receptacle of the container using the
handles, and introduce two thirds of
the container in a downward direc-
tion. When encountering noticeable
resistance, manually push into the final
position. Snap handles into place at the
side of the filter receptacle.
filter and fit onto the guide pipe when
closing the housing lid.
Close the service valve.
ÖWAMAT 12, 14, 15, 16
loading

Este manual también es adecuado para:

Owamat 14Owamat 15Owamat 16