Tecnomac AQUAMAC 100 Manual De Instrucciones página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
GB
(the material is shipped in the left hand
air inlet duct);
b) Install the water cooler in a well ventilated
place (at least 20 cm from any adjacent
walls), ensuring it is perfectly level;
c) Connect the unit to the mains water sup-
ply (drinking water) using the water sup-
ply hose and seals enclosed with the
appliance.
If the water pressure is higher than 5 Atm,
fit a pressure reducer valve (not included
in the appliance outfit).
d) Screw the supplied hose to the overflow
outlet and then connect it to the drain
hose, ensuring that the drain is unob-
structed
IMPORTANT:
For water coolers supplied with pressure ves-
sel/pump unit:
1) Before starting up the appliance, ensure that
3. WALL BRACKET KIT ASSEMBLY INSTRUCTIONS
1) Remove the rear panel from the appliance
2) Secure the 2 bracket coupling pins in the
holes on the cross-member at the top rear of
the unit
3) Secure the bracket to the wall by means of 3
wall fixings (at least 12 mm dia.). The unit
can be installed only on perfectly solid load-
bearing walls.
14
W W
W W
THE FOLLOWING PROCEDURES
MUST BE PERFORMED
BY A LICENSED INSTALLER
FOR 100 LITRE MODEL
e) When choosing the place of installation,
bear in mind that ambient temperature
must remain strictly within the range +5
°C to +40 °C.
4) If you wish to use the water cooler with a
mixer/batcher:
a) The pump switch
must be set to "0" - OFF
b) The cock between expansion tank and
pump must be in the CLOSED position
c) The two-core connection cable must be
connected to the batcher-mixer termi-
nals.
A A
R R
N N
I I
N N
G G
! !
A A
R R
N N
I I
N N
G G
! !
the pressure vessel pump impeller is free-
running (prolonged disuse can lead to seiz-
ing due to lime scale residues).
Remove the rear panel to gain access to the
pressure vessel.
4) Lift the appliance until you engage the wall
bracket with the support pins.
5) Insert a spacer (wood, etc.) between the
wall and the lower cross-member of the
appliance so that the rear of the unit is per-
fectly parallel to the wall.
on the front panel
Tabla de contenido
loading

Este manual también es adecuado para:

Aquamac 150Aquamac 200

Tabla de contenido