3. Use the [<][>] keys to scroll to the zone label to be programmed and press [*] or enter the zone
number (e.g., 001, for zone label 1).
4. Use the [<][>] keys to scroll to the desired character's location, using the [<][>] keys.
5. Enter the number of the corresponding character group until the desired character is displayed
(see the following table). Example, press the "2" key three times to enter the letter "F". Press
the "2" key four times to enter the number "2". Press [*], then scroll to "Save". Press [*]
[1] - A, B, C, 1
[2] - D, E, F, 2
[3] - G, H, I, 3
[4] - J, K, L, 4
again to save the label. To delete a character, use the [<][>] keys to move the cursor under the
character, then press [0]. If any key other than [<][>] is pressed before [0], the cursor moves
one space to the right and deletes that character.
CHANGE CASE – Will toggle the next letter entries between upper case (A, B, C...) and lower
case letters (a, b, c...).
ASCII ENTRY – Used to enter uncommon characters. Valid entries range from 000 to 255. Use the
[<][>] keys to scroll through the characters or enter a 3-digit number from 000-255. Press [*] to
enter the character into the label.
CLEAR TO END – Clears the display from the character where the cursor was located to the end of
the display.
CLEAR DISPLAY – Clears the entire label.
6. Continue from Step 2, until all labels are programmed.
Label Library
The Label Library is a database of words commonly used when programming labels. Individual
words can be combined as needed (e.g., Front + Door). Each line of the display supports a maxi-
mum of 14 characters. If a word will not fit on a line, scroll right until the cursor appears at the first
character of the second line and then add the word.
To program a custom label using the Label Library:
1. Press [*][8][Installer Code][000][001].
2. Enter [001] (to program the label for zone 01), or use the [<][>] keys to scroll to the Zone
Labels and then press [*]. The current label name is displayed for that zone.
3. Press [*] to open the menu.
4. Press [*] again to select the "Word Entry" option.
5. Enter the 3-digit number corresponding to a word (see Words Library) or use the [<][>] keys
to view words in the library.
6. Press [*] to select the word.
7. To add another word, repeat the previous procedures from step 3.
8. To add a space, press the right scroll key [>].
9. To clear characters, select "Clear to End" or "Clear Display" from the menu.
10.To save the current label and exit, press [#].

Broadcast LCD Labels

If more than one LCD keypad is present on the system, labels programmed on one keypad will be
broadcast to all other LCD keypads, after the change is confirmed.
Change Brightness/Contrast/Buzzer
LCD Keypads
1. Press [*][6][Master Code].
2. Use the [<][>] keys to scroll to either Bright Control, Contrast Control, or Buzzer Control.
3. Press [*] to select one of the following settings:
• Brightness/LED Bar Control: 15 backlighting levels are available.
• Contrast Control: 15 different display contrast levels are available.
• Buzzer Control: 15 different buzzer control levels are available.
4. Use the [<][>] keys to scroll to the desired setting.
[5] - M, N, O, 5
[9] - Y, Z, 9, 0
[6] - P, Q, R, 6
[0] - Space
[7] - S, T, U, 7
[*] - Select
[8] - V, W, X, 8
[#] - Escape

Keypad Programming

1. Press [*][8][Installer Code].
2. Select one of the programming options identified in the following.
[860] Keypad Slot Number
Not for programming; the two-digit slot number is displayed for informational purposes only.
[861]-[876] Keypad Programming Sections
[000] Address of Partition
A 2-digit entry is required to assign the keypad to a partition. Entering 00 assigns the keypad as
Global. Valid entries are 00-32. The default is 01.
[001]-[005] Keypad Function Key Programming
To program a function key:
1. Press [*][8][Installer Code].
2. Enter [861]-[876] for keypad programming.
3. Enter [001]-[005] for function keys 1-5 or use the [<][>] keys and press [*].
4. Enter a 2-digit number to assign a function key operation - [00]-[68]. See the following table.
5. Repeat from step 3 until all function keys are programmed.
6. Press [#] twice to exit Installer Programming.
[001]-[005] Function Key Assignment
Function Key
Button
[001]
Key 1
[002]
Key 2
[003]
Key 3
[004]
Key 4
[005]
Key 5
Keypad Function Keys
Refer to your system installation manual for a complete list of available function key options.
[00] - Null
[21] - [*][7][1]Command Output 1 [61]-[68] - Partition Select 1-8
[02] - Instant Stay Arm
[22] - [*][7][2]Command Output 2
[03] - Stay Arm
[23] - [*][7][3]Command Output 3
[04] - Away Arm
[24] - [*][7][4]Command Output 4
[05] - [*][9] No-Entry Arm
[29] - Bypass Group Recall
[06] - [*][4] Chime ON/OFF [31] - Local PGM Activate
[07] - [*][6][----][4] System Test [32] - Bypass Mode
[09] - Night Arm
[33] - Bypass Recall
[12] - Global Stay Arm
[34] - User Programming
[13] - Global Away Arm
[35] - User Functions
[14] - Global Disarming
[37] - Time & Date Program
[16] - [*][0] Quick Exit
[39] - Trouble Display
[17] - Arm Interior
[40] - Alarm Memory
[011] Keypad Input/Output Programming
Zone or PGM
Default
Number
000
Valid
Default
Function
Range
I_____I_____I
00–68
03
Stay Arm
00–68
04
Away Arm
I_____I_____I
Chime ON/
00–68
06
I_____I_____I
OFF
Command
22
I_____I_____I
00–68
Output 2
Quick
I_____I_____I
00–68
16
Exit
I_____I_____I_____I