Aqua Medic Titan 150 Manual De Instrucciones página 4

Ocultar thumbs Ver también para Titan 150:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
With the purchase of an Aqua Medic cooling unit, you have selected a top quality product. It has been specifically
designed for the cooling of closed water cycles like fresh and salt water aquaria.
The Titan coolers are supplied with heat exchanger made from salt water proof Titanium steel. These heat
exchangers are corrosion-resistant and free of contaminations. The cooling units can be used in fresh and salt
water as well as in various chemicals.
The coolers have a one-phase cooling system containing the cooling medium R 134 a (FCKW-free). They work
with capillary injection as control system.
1. Product description
The Aqua Medic cooling units Titan 150, 500, 1500 and 2000 are supplied with:
- a temperature computer incl. digital display
- connections for water in- and outlet
- main switch and fuse to be changed from outside (not valid for Titan 2000)
- solid cover made of plastic and metal
2. Set-up and installation
1. The cooling unit must be set up at a well-ventilated place. The complete heat taken out of water by
the unit and the waste heat of the unit itself are emitted at the unit into the air. A build-up of heat directly
at the cooling unit leads to a heavily reduced cooling power output. Therefore, a sufficient ventilation is
essential. The exhaust air must be able to escape from the back (where the water connections are placed).
The environmental temperature should not exceed 35 °C.
2. The cooling unit has to be connected at the connecting pieces to a closed water cycle. It is recommended to
place the unit below the water surface. In case of leakage of the angled connecting piece, push union nut
back and tighten the internal screw connection again firmly.
3. Switch the water flow on. It is important that the water flows continuously through the cooler.
Because the temperature-sensor is placed inside the unit, the heat exchanger cannot freeze in case of a
failure of water supply.
The fow rates are:
Titan 150:
minimum
Titan 500:
minimum
Titan 1500:
minimum
Titan 2000:
minimum 2,000, maximum 4,000 litres/h
4. Before starting, the cooler should stand up straight for at least 1 hour. Connect it to 230 V power source and
switch the unit on (plug in the mains and switch on). Now, the actual water temperature is shown on the
display. Because the thermo sensor is placed in the water inlet, always a temperature which corresponds to
the temperature in the tank is shown.
Attention:
Cooling unit may not be used under pressure!
Maximum height below water level: 150 cm.
3. Temperature control
The cooling units of the TITAN series are supplied with a digital temperature controller.
Programming: The display shows the actual temperature of the water.
Check the set point: Press the „SET" button (shortly). Now, the set point is shown in the display and a LED
(top, left) flashes. After some seconds, the unit switches back to the actual temperature.
Adjustment of the set point: Press the „SET"-button for approx. 5 sec. Now, the set value is displayed and
flashes. The set value can now be changed in steps of 1 °C, using the ▲ and ▼ buttons. By pressing the "SET"
button again, the set point is saved.
4
Operation Manual ENG
200, maximum 1,500 litres/h
500, maximum 2,000 litres/h
800, maximum 2,500 litres/h
loading

Este manual también es adecuado para:

Titan 500Titan 1500Titan 2000