h. Remotely Controlling the Central Unit
The central unit can be remotely switched on and off. To do so, dial the number of the telephone line
connected to the unit. The alarm unit will answer the call after the number of rings programmed in "vibrant
ring". Press the user code first and confirm with #, followed by
1 to enter the ARM mode
2 to enter the DISARM mode
3 to listen to built-in microphone of the central unit
4 to cancel the call.
5. Commands on the Remote Control and the Help Alarm
The 4-key remote control will be encoded
automatically. The commands can be used as soon
as the remote control is saved into the system:
• DISARM: alarm system deactivation
• HOME ARM: entering the HOME or GUARD
mode
• AWAY ARM: entering the AWAY mode
• HELP: panic function activation
Remark: Follow these steps to assign a different code when 2 or mode remote controls have been encoded
similarly:
Open the remote control by unscrewing the screw at the back. Remove the battery. Hold any key on the
remote control pressed and reinstall the battery. The LED on the remote control will blink. Release the
pressed key. The remote control has learned a new address. Close the remote control and reprogram into
the system.
Press the panic button on the help remote thrice to activate the panic alarm.
6. The PIR Sensor
Open the motion sensor by unscrewing the 3
screws at the back. The PIR sensor can detect
motion in 2 ways. By setting the jumper in the
first mode (1x) the sensor will trigger the alarm
immediately after detecting motion. By setting
the jumper in the second mode (2x) the sensor will wait for a second motion detection after the first one. This
mode can be used to reduce the detection of motion caused by house pets.
Next, address the sensor. To define the origin of the signal, the address must be different than the address of the
all other sensors.
Install a 9V battery and close the sensor. Wait for ± 60 seconds until the sensor has stabilised. Now, program and
assign the sensor to a zone through the menus of the central unit.
Remark:
o The LED will blink when the battery is almost drained (<7V).
o Do not install the sensor onto a metal support or plate.
o Keep the sensor away from direct sunlight and temperature variations (air conditioner, heating...).
HAM06WS_v2