Pan Inversion
Normal: Panning movement is not inversed.
Pan inversion: Panning movement is inversed
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP button to select
(normal) or
 Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Tilt Inversion
Normal: Tilt movement is not inversed.
Tilt inversion: tilt movement is inversed
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to select
(normal) or
 Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Led Display
Display on: display is always on.
Display off: display is off when not used.
 Press the MENU button until the display shows
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to select
(display always on) or
 Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Display Inversion
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.
 Press the MENU button until
is blinking on the display. (normal display)
 Use the ENTER button to change to the mode
stored after 8 seconds. Or press the ENTER button again return to the mode
 To go back to the functions press the MENU button.
Focus Adjust
Used to help you adjusting the focus of the light beam and gobos.
 Press the MENU button untill
is blinking on the display.
 Press the ENTER button so the unit goes to the "tilt 90°" position.
 Press the ENTER button so the unit goes to the "pan 0°" position.
 Press the ENTER button so the unit goes to the "pan 90°" position.
 Press the ENTER button so the unit goes to the "pan 180°" position.
 Press the ENTER button so the unit goes to the "pan 270°" position.
In the Previous 5 steps you are able to adjust the focus with the UP/DOWN buttons on the unit (the display
shows the current focus status).
Attention: please note that you can only set an "average focus" for all 5 positions, so it is not possible to set
the focus perfectly sharp for all directions.
 To go back to the functions press the MENU button.
Briteq
®
OPERATION MANUAL
(pan inversion) mode.
(tilt inversion) mode.
.
(display off when not used).
(display inversion), the option will be automatically
(normal display).
7/69
ENGLISH
Used to activate the internal "self-test" program which shows all possibilities of the unit.
 Press the MENU button until
 Press the ENTER button to start the internal self-test program.
 To go back to the functions press the MENU button.
Used to show the temperature inside the lamp compartment
 Press the MENU button until the
 Press the ENTER button and the ambient temperature of lamp will show on the display.
 To go back to the functions press the MENU button again.
Used to show the n° of working hours of the unit.
 Press the MENU button until
 Press the ENTER button to show the n° of working hours in the display.
 To go back to the functions press the MENU button.
Used to switch the lamp ON/OFF so you can cool the lamp with the internal fans before
transportation
 Press the MENU button until
 Press ENTER button so the display starts blinking.
 Use DOWN and UP button to select the
 Once the mode is selected, press the ENTER button to setup
(or automatically return to the main functions without any change after 8 seconds)
 To go back to the functions without any change press the MENU button again.
Used to force a reset of the unit.
 Press the MENU button until
 Press the ENTER to reset all channels to their standard position.
 To go back to the functions press the MENU button.
Please also check the chapter about the DMX-channel configuration of the unit to find out how you can force
a reset by DMX.
 HOME POSITION ADJUST
 Press MENU button for at least 5 seconds to
go into offset mode
 Now you can adjust the home position ( this is
the zero position )
 When you want to adjust gobo and color
home position, you should run
first
 The functions are shown below:
BT250S
Briteq
®
Self-Test
is blinking on the display.
Ambient temperature of lamp
sign is blinking on the display.
Fixture Hours
is blinking on the display.
Lamp Display
is blinking on the display.
(Lamp on) or
Reset
is blinking on the display.
mode
8/69
OPERATION MANUAL
(Lamp off) mode.