ENGLISH
LAMP (RE)PLACEMENT
In
case
of
replacement
of
maintenance, do not open the fixture within 10
minutes until the unit cools down after switching
off. Always unplug the unit before servicing!
Always use the same type of spare parts (bulbs,
fuses, etc.) When replacing parts, please only
genuine spare parts.
Switch off the unit and unplug the mains cable.
Wait for about 10 minutes until the unit has been cooled down.
Unscrew the knob that closes the lamp compartment.
On the inside you will see the lamp socket.
Unplug the old lamp. Hold the lamp socket while unplugging
the lamp!
Hold the lamp socket while pressing the new lamp gently in the socket.
Attention! Check the label on the backside of the device or see the technical specifications in this manual
to know which lamp should be used. Never install lamps with a higher wattage! Lamps with higher wattage
generate temperatures the device was not designed for.
Don't touch the bulb with bare hands! This drastically shortens the lifespan of the lamp. If you touched the
lamp, clean it with a cloth and a little denatured alcohol. Wipe the lamp off before installing.
Be sure that the wires don't touch the lamp.
Close the lamp compartment.
Done!
EXCHANGING THE LENS
In case of replacement of the lens, do
not open the fixture within 10 minutes
until
the
unit
cools
down
after
switching off. Always unplug the unit
before servicing! Switch off the unit
and unplug the mains cable.
Wait for about 10 minutes until the unit has been
cooled down.
Unscrew
the
knob
that
closes
the
lamp
compartment.
Turn the lamp socket backwards, as far as
possible, using the focus knob on the back panel.
(see A on the picture)
Remove the safety ring by pressing the ring
outwards. (see B on the picture)
Press the 2 upper metal clips (holding the lens) a little
outwards, so you can easily remove the lens (See C on
the picture)
Remove the lens and put the new lens in place.
Press both upper metal clips inwards.
Put the safety ring back in place.
Move the lamp socket back to it's original position.
Close the lamp compartment.
Done!
JB SYSTEMS
®
OPERATION MANUAL
the
lamp
or
3/30
THEATRE SPOT 500W + 1000W
ENGLISH
OVERHEAD RIGGING
Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
Don't cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
OPERATING INSTRUCTIONS
Once connected to the mains the device starts running.
Regular breaks during operation are essential to maximize the life of this device as it is not designed for
continual use.
Do not switch the unit on and off in short time intervals as this reduces the lamp life.
The units' surface temperature may reach up to 125°C for the 500W version and 160°C for the 1000W
version. Don't touch the housing with bare-hands during its operation.
Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.
In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
Important: Never look directly into the light source! Don't use the effect in the presence of persons
suffering from epilepsy.
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
JB SYSTEMS
®
OPERATION MANUAL
4/30
THEATRE SPOT 500W + 1000W