Trouble-shooting.
Symptom
Appliance will not
switch on
While drying the appliance
switches off and cannot be
immediately restarted
Motor runs, but blows
only cold air
the appliance fails to cut
out
continuous operation
version
Possible causes and their remedies
St 2400,
Power supply is dead
StH 2400 z
check fuses/circuit breakers
Connecting cables loose or broken
Aswitch off and remove from the power
supply, and test wiring connections and
cables with a circuit tester. if necessary,
replace the timer electronic
St 2400 E,
Power supply is dead
St 2400 Ec
check fuses/circuit breakers
St 2400 ES
Connecting cables loose or broken
switch off and remove from the power
supply, and test wiring connections and
cables with a circuit tester. if necessary,
replace the timer electronic with infra red
sensor
All versions
Thermostat has triggered
allow appliance to cool down for a few
minutes and then switch on again
All versions
Heating has failed
check the electric heating leads with a
circuit-tester in case of a broken wire if
necessary, replace the heating
St 2400,
When operated, the push-button sticks
StH 2400 z
in
release the push-button again manually
Push-button does not spring back out
and stays in
have the push-button replaced
St 2400 E,
Infra-red sensor does not switch off
St 2400 Ec
replace the timer electronics with infra-red
St 2400 ES
sensors
Infra-red sensor has been interfered
with and is covered
remove the covering
Dryer is installed too close to an object
and this object reflects and switches the
appliance on continuously
relocate either the dryer or the object
13 - GB