GB
Ch. 2 Limitations
SUB 3S electropumps are suitable to pump clear water that contains no dissolved gases.
The electropumps of SUB 3S series are multiphase centrifugal and submergible pumps.
Technical Data
Mains voltage / Frequency
Absorbed power
Type of protection / Insulation class
Delivery fitting
Maximum flow rate *
Maximum head *
Maximum immersion depth
Power cable
Weight
Maximum dimension of pumped solid particles
Maximum admitted working pressure
Maximum diameter of the well
Maximum temperature of the pumped fluid
Maximum number of starts per hour
Minimum priming level (A)**
Connection level (C)**
Stop level (D)**
(*) The specifications hereunder are referred to a configuration with a free and unreduced delivery mouth
(**) Measurements are expressed in millimetres.
Sound pressure level (Lpa) equal to or less than 70 dB(A)
Sound emission values obtained in conformity with the EN 12639 standard
Ch. 3 Installation (see Fig. 1)
DANGER
Electric shock
risk
DANGER
DANGER
Use the handle provided to transport or lift the pump.
To use the pump in permanent installations with rigid pipes, to install a check valve to avoid the fluid being re-circulated
once the pump is stopped. The installation of a quick closing fitting in a convenient position facilitates cleaning and
maintenance operations.
The dimensions of the collection container should reduce to the minimum the number of starts per hour (see LIMITATIONS
- Technical data).
To use the pump for temporary applications, install a flexible pipe and connect it to the pump using a pipe holder. To
immerse the pump, use a rope and fix it to the handle.
SUB 3S pumps have a pre-set floating switch. To change the setting, it is necessary to increase or reduce the length of
the floating switch cable by sliding it in the slot on the handle (See Fig. 1).
Install the pump at least 50 cm from the bottom of the well to avoid taking in sand, mud, etc
6
The electropump cannot be used to move inflammable or dan-
WARNING
gerous liquids.
WARNING
Verify that the electropump never runs without liquids.
When installing, please ensure electropump is disconnected from electrical
supply. Pumps in this series are not suitable for use in a swimming pool and
the relevant cleaning and servicing operations.
To prevent possible injuries to people, avoid inserting hands into the mouth of the pump
if this is connected to the mains.
This appliance can be used by children aged 8 years or over and by persons with limited
physical, sensory or intellectual capabilities, or with limited experience and knowledge,
provided that they are supervised or have been instructed in the safe use of the appliance
and are aware of the dangers involved. Children must not be allowed to play with the
appliance. Cleaning and user maintenance must not be carried out by children unless
they are supervised
SUB 3S
230 V ~ 50 Hz
800 Watt
IP 68 / F
41,90 mm (1"1/4 M)
6000 l/h
30 m
8 m
10 m
7,4 Kg
≤ 2 mm
7 bar
500 mm
40° C
30, uniformly distributed
30 mm
340 mm
185 mm
2
GB