store number for gate control function (max 42)
MAC+39xxxxxx
delete number for gate control function
DAC+39xxxxxx
total deletion of gate control list (except for the first 8 numbers)
DAC
time for gate control activation s= 00 (bistable)~ 59
TAC:ss
alarm text when input 1 is under tension (max. 100 characters)
TIN1A:xxxxxxxxxxx
alarm text when no tension present on input 1 (max. 100 characters)
TIN1B:xxxxxxxxxxx
alarm text when input 2 is under tension (max. 100 characters)
TIN2A:xxxxxxxxxxx
alarm text when no tension present on input 2 (max. 100 characters)
TIN2B:xxxxxxxxxxx
start‐up text message (max 100 characters)
TSU:xxxxxxxxxxx
disable reply for multiple message
RISP,
Troubleshooting
9.
Problem
Green LED LD5 is off
Green LED LD5 flashes
cyclically at 1 Hz
frequency
The device does not
send a reply to the
configuration SMS
31.05.2011
HAMGSM133
Possible reason
No supply tension or
inverted polarity
No GSM network
available or signal not
strong enough
Reply to the message
with command RISP is
disabled or there is no
credit in the SIM Card.
9
(password required)
(password required)
(password required)
(default: alarm!! input 1 high )
(default: alarm!! input 1 low)
(default: alarm!! input 2 high )
(default: alarm!! input 2 low)
(default: system start‐up)
Possible solution
Check power supply
cable
Change the position of
the external GSM
antenna
Do not use the RISP
command in the SMS,
or recharge the SIM
Card.
©Velleman nv